Schneider Electric HLA36150U31X Molded Case Circuit Breaker 600V 150A

(No reviews yet) Write a Review
SKU:
HLA36150U31X
UPC:
785901947660
Condition:
New
Wire Stripping Length:
16 mm
Net Weight:
2.2 kg
Network Frequency:
50/60 Hz
Device Application:
distribution
Quantity Per Set:
1
Eu Rohs Directive:
Compliant with Exemptions
Warranty:
18 months
Electrical Connection:
I-Line connection, line || lugs, load
[Ics] Rated Service Breaking Capacity:
125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Mounting Mode:
I-Line bracket)
Pollution Degree:
3 IEC 60947-1
Product Certifications:
UL || CSA || NOM
Width:
104 mm
Local Signalling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Protected Poles Description:
3t
Range:
PowerPact
Suitability For Isolation:
yes IEC 60947-2
Sustainable Offer Status:
Green Premium product
Breaking Capacity Code:
L
Trip Unit Name:
MicroLogic 3.2
Breaking Capacity:
125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
Circuit Breaker Application:
HACR rated
Utilisation Category:
category A
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Trip Unit Technology:
electronic, standard, MicroLogic 3.2, LI
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Ambient Air Temperature For Storage:
-50-85 °C
Color:
Black
Line Rated Current:
150-150 A
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Mercury Free:
Yes
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Mounting Height:
4.5 in
Rohs Exemption Information:
Yes
Quality Labels:
CE
Product Or Component Type:
circuit breaker
Ambient Air Temperature For Operation:
-2-70 °C
Poles Description:
3P
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Phase Connection:
ABC
Communication Interface:
Modbus || Ethernet
Product Name:
PowerPact H
Depth:
86 mm
Environmental Disclosure:
ENVPEP2206028EN
Control Type:
toggle
Continuous Current Rating:
0.8
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Circularity Profile:
ENVEOLI2206028EN
Pvc Free:
Yes
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Ip Degree Of Protection:
front cover IP40 IEC 60529
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Terminal Identifier:
AL150HD
Mounting Support:
bracket
Height:
163 mm
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
  • Schneider Electric HLA36150U31X Molded Case Circuit Breaker 600V 150A
  • Schneider Electric HLA36150U31X Molded Case Circuit Breaker 600V 150A
  • Schneider Electric HLA36150U31X Molded Case Circuit Breaker 600V 150A
$7,288.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides Micrologic Standard with a 3.2 trip unit and an LI function with a breaking capacity of 50kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 150A, 3 pole, circuit breaker has a breaking capacity of 50kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose