Schneider Electric HLL36045 Molded Case Circuit Breaker 600V 45A
Schneider Electric
$2,849.00
PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 50kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 45A, 3 pole, circuit breaker has a breaking capacity of 50kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Warranty:
- 18 months
- Continuous Current Rating:
- 0.8
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Net Weight:
- 2.2 kg
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Rohs Exemption Information:
- Yes
- Depth:
- 86 mm
- Eu Rohs Directive:
- Compliant with Exemptions
- Width:
- 104 mm
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-3
- Poles Description:
- 3P
- Mounting Support:
- lug
- Height:
- 163 mm
- Electrical Connection:
- lugs, line || lugs, load
- Tightening Torque:
- 5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
- Ambient Air Temperature For Storage:
- -50-85 °C
- Mounting Mode:
- unit mount lug)
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Device Application:
- distribution
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Line Rated Current:
- 45-45 A
- Breaking Capacity:
- 125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
- Range:
- PowerPact
- Protected Poles Description:
- 3t
- Product Name:
- PowerPact H
- Awg Gauge:
- AWG 14...AWG 3/0 aluminium/copper terminal
- Product Certifications:
- UL || CSA || NOM
- Ambient Air Temperature For Operation:
- -2-70 °C
- Mercury Free:
- Yes
- Circularity Profile:
- ENVEOLI2206027EN
- Wire Stripping Length:
- 16 mm
- Terminal Identifier:
- AL150HD
- Product Or Component Type:
- circuit breaker
- Magnetic Tripping Current:
- 850-850 A
- Suitability For Isolation:
- yes IEC 60947-2
- Quantity Per Set:
- 1
- Trip Unit Technology:
- thermal-magnetic
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Control Type:
- toggle
- Circuit Breaker Application:
- HACR rated
- Sustainable Offer Status:
- Green Premium product
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Magnetic Hold Current:
- 400 A
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Communication Interface:
- Modbus || Ethernet
- Utilisation Category:
- category A
- Quality Labels:
- CE
- Pvc Free:
- Yes
- Network Frequency:
- 50/60 Hz
- Pollution Degree:
- 3 IEC 60947-1
- Color:
- Black
- Breaking Capacity Code:
- L
- Environmental Disclosure:
- ENVPEP2206027EN
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- [Ics] Rated Service Breaking Capacity:
- 125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View