Schneider Electric HLP36150 Molded Case Circuit Breaker 600V 150A

(No reviews yet) Write a Review
SKU:
HLP36150
UPC:
7.85902E+11
Condition:
New
Circuit Breaker Application:
HACR rated
Product Certifications:
UL || CSA || NOM
Utilisation Category:
category A
Poles Description:
3P
Terminal Identifier:
AL150HD
Line Rated Current:
150-150 A
Breaking Capacity Code:
L
Communication Interface:
Modbus || Ethernet
Range:
PowerPact
Quantity Per Set:
1
Pollution Degree:
3 IEC 60947-1
Local Signalling:
switched off (OFF) 1 trip indicator green)
Protected Poles Description:
3t
[Ics] Rated Service Breaking Capacity:
125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Ambient Air Temperature For Storage:
-50-85 °C
Depth:
86 mm
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Continuous Current Rating:
0.8
Product Or Component Type:
circuit breaker
Product Name:
PowerPact H
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Ambient Air Temperature For Operation:
-2-70 °C
Sustainable Offer Status:
Green Premium product
Rohs Exemption Information:
Yes
Mounting Support:
lug
Network Frequency:
50/60 Hz
Circularity Profile:
ENVEOLI1311006EN
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Net Weight:
2.2 kg
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Environmental Disclosure:
ENVPEP1311006EN
Magnetic Hold Current:
900 A
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Suitability For Isolation:
yes IEC 60947-2
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Eu Rohs Directive:
Compliant
Mercury Free:
Yes
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Pvc Free:
Yes
Color:
Black
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Trip Unit Technology:
thermal-magnetic
Electrical Connection:
terminal nut, line || lugs, load
Ip Degree Of Protection:
front cover IP40 IEC 60529
Wire Stripping Length:
16 mm
Device Application:
distribution
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Height:
163 mm
Warranty:
18 months
Breaking Capacity:
125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
Magnetic Tripping Current:
1700-1700 A
Control Type:
toggle
Quality Labels:
CE
Width:
104 mm
Mounting Mode:
unit mount lug)
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric HLP36150 Molded Case Circuit Breaker 600V 150A
  • Schneider Electric HLP36150 Molded Case Circuit Breaker 600V 150A
$10,123.50

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 50kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has terminal nuts on the line side and lugs on the load side. This PowerPacT H, 150A, 3 pole, circuit breaker has a breaking capacity of 50kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.