- Circuit Breaker Application:
- HACR rated
- Product Certifications:
- UL || CSA || NOM
- Utilisation Category:
- category A
- Poles Description:
- 3P
- Terminal Identifier:
- AL150HD
- Line Rated Current:
- 150-150 A
- Breaking Capacity Code:
- L
- Communication Interface:
- Modbus || Ethernet
- Range:
- PowerPact
- Quantity Per Set:
- 1
- Pollution Degree:
- 3 IEC 60947-1
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Protected Poles Description:
- 3t
- [Ics] Rated Service Breaking Capacity:
- 125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Ambient Air Temperature For Storage:
- -50-85 °C
- Depth:
- 86 mm
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Continuous Current Rating:
- 0.8
- Product Or Component Type:
- circuit breaker
- Product Name:
- PowerPact H
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-3
- Ambient Air Temperature For Operation:
- -2-70 °C
- Sustainable Offer Status:
- Green Premium product
- Rohs Exemption Information:
- Yes
- Mounting Support:
- lug
- Network Frequency:
- 50/60 Hz
- Circularity Profile:
- ENVEOLI1311006EN
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Net Weight:
- 2.2 kg
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Environmental Disclosure:
- ENVPEP1311006EN
- Magnetic Hold Current:
- 900 A
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Suitability For Isolation:
- yes IEC 60947-2
- Awg Gauge:
- AWG 14...AWG 3/0 aluminium/copper terminal
- Eu Rohs Directive:
- Compliant
- Mercury Free:
- Yes
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Pvc Free:
- Yes
- Color:
- Black
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Trip Unit Technology:
- thermal-magnetic
- Electrical Connection:
- terminal nut, line || lugs, load
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Wire Stripping Length:
- 16 mm
- Device Application:
- distribution
- Tightening Torque:
- 5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
- Height:
- 163 mm
- Warranty:
- 18 months
- Breaking Capacity:
- 125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
- Magnetic Tripping Current:
- 1700-1700 A
- Control Type:
- toggle
- Quality Labels:
- CE
- Width:
- 104 mm
- Mounting Mode:
- unit mount lug)
- QN-QUOTE-REQUEST:
- true