- Phase Connection:
- ABC
- Poles Description:
- 3P
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Breaking Capacity:
- 200 kA 240 V AC 50/60 Hz UL 489 || 200 kA 480 V AC 50/60 Hz UL 489 || 100 kA 600 V AC 50/60 Hz UL 489
- Protected Poles Description:
- 3t
- Suitability For Isolation:
- yes IEC 60947-2
- Electrical Connection:
- I-Line connection, line || lugs, load
- Awg Gauge:
- AWG 14...AWG 3/0 aluminium/copper terminal
- Depth:
- 86 mm
- Height:
- 163 mm
- Terminal Identifier:
- AL150HD
- Wire Stripping Length:
- 16 mm
- Mercury Free:
- Yes
- Mounting Mode:
- I-Line bracket)
- Pvc Free:
- Yes
- Product Name:
- PowerPact H
- Communication Interface:
- Modbus || Ethernet
- Trip Unit Name:
- MicroLogic 3.2
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Eu Rohs Directive:
- Compliant with Exemptions
- Network Frequency:
- 50/60 Hz
- Mounting Height:
- 4.5 in
- Ambient Air Temperature For Storage:
- -50-85 °C
- [Ics] Rated Service Breaking Capacity:
- 150 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 125 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 75 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 690 V AC 50/60 Hz IEC 60947-2
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Quality Labels:
- CE
- Line Rated Current:
- 60-60 A
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Quantity Per Set:
- 1
- Device Application:
- distribution
- Net Weight:
- 2.2 kg
- Product Certifications:
- UL || CSA || NOM
- Range:
- PowerPact
- Mounting Support:
- bracket
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Tightening Torque:
- 5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
- Local Signalling:
- ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
- Color:
- Black
- Width:
- 104 mm
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Trip Unit Technology:
- electronic, standard, MicroLogic 3.2, LI
- Pollution Degree:
- 3 IEC 60947-1
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-3
- Product Or Component Type:
- circuit breaker
- Control Type:
- toggle
- Breaking Capacity Code:
- R
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Continuous Current Rating:
- 0.8
- Sustainable Offer Status:
- Green Premium product
- Circuit Breaker Application:
- HACR rated
- Environmental Disclosure:
- ENVPEP2206028EN
- Rohs Exemption Information:
- Yes
- Ambient Air Temperature For Operation:
- -2-70 °C
- Circularity Profile:
- ENVEOLI2206028EN
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Utilisation Category:
- category A