Schneider Electric HRA36060U31X Molded Case Circuit Breaker 600V 60A

(No reviews yet) Write a Review
SKU:
HRA36060U31X
UPC:
7.85902E+11
Condition:
New
Phase Connection:
ABC
Poles Description:
3P
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Breaking Capacity:
200 kA 240 V AC 50/60 Hz UL 489 || 200 kA 480 V AC 50/60 Hz UL 489 || 100 kA 600 V AC 50/60 Hz UL 489
Protected Poles Description:
3t
Suitability For Isolation:
yes IEC 60947-2
Electrical Connection:
I-Line connection, line || lugs, load
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Depth:
86 mm
Height:
163 mm
Terminal Identifier:
AL150HD
Wire Stripping Length:
16 mm
Mercury Free:
Yes
Mounting Mode:
I-Line bracket)
Pvc Free:
Yes
Product Name:
PowerPact H
Communication Interface:
Modbus || Ethernet
Trip Unit Name:
MicroLogic 3.2
Ip Degree Of Protection:
front cover IP40 IEC 60529
Eu Rohs Directive:
Compliant with Exemptions
Network Frequency:
50/60 Hz
Mounting Height:
4.5 in
Ambient Air Temperature For Storage:
-50-85 °C
[Ics] Rated Service Breaking Capacity:
150 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 125 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 75 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 690 V AC 50/60 Hz IEC 60947-2
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Quality Labels:
CE
Line Rated Current:
60-60 A
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Quantity Per Set:
1
Device Application:
distribution
Net Weight:
2.2 kg
Product Certifications:
UL || CSA || NOM
Range:
PowerPact
Mounting Support:
bracket
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Local Signalling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
Color:
Black
Width:
104 mm
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Trip Unit Technology:
electronic, standard, MicroLogic 3.2, LI
Pollution Degree:
3 IEC 60947-1
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Product Or Component Type:
circuit breaker
Control Type:
toggle
Breaking Capacity Code:
R
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Continuous Current Rating:
0.8
Sustainable Offer Status:
Green Premium product
Circuit Breaker Application:
HACR rated
Environmental Disclosure:
ENVPEP2206028EN
Rohs Exemption Information:
Yes
Ambient Air Temperature For Operation:
-2-70 °C
Circularity Profile:
ENVEOLI2206028EN
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Utilisation Category:
category A
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric HRA36060U31X Molded Case Circuit Breaker 600V 60A
  • Schneider Electric HRA36060U31X Molded Case Circuit Breaker 600V 60A
$4,171.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides Micrologic Standard with a 3.2 trip unit and an LI function with a breaking capacity of 100kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 60A, 3 pole, circuit breaker has a breaking capacity of 100kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose