- Wire Stripping Length:
- 25 mm
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Product Or Component Type:
- circuit breaker
- Environmental Disclosure:
- ENVPEP2206031EN
- Electrical Connection:
- I-Line connection, line || lugs, load
- Ip Degree Of Protection:
- front cover IP40
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Mounting Mode:
- I-Line bracket)
- Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Terminal Identifier:
- AL175JD
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- Tightening Torque:
- 25-25 N.m 25-95 mm² (AWG 4...AWG 4/0)
- Height:
- 191 mm
- Sustainable Offer Status:
- Green Premium product
- Breaking Capacity Code:
- D
- Ambient Air Temperature For Storage:
- -50-85 °C
- Net Weight:
- 2.4 kg
- Circularity Profile:
- ENVEOLI2206031EN
- Continuous Current Rating:
- 0.8
- Pvc Free:
- Yes
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Magnetic Tripping Current:
- 1750-1750 A
- Line Rated Current:
- 175-175 A
- Ambient Air Temperature For Operation:
- -2-70 °C
- Rohs Exemption Information:
- Yes
- Suitability For Isolation:
- yes IEC 60947-2
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Phase Connection:
- AB
- Communication Interface:
- Modbus
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Awg Gauge:
- AWG 4...AWG 4/0 aluminium/copper terminal
- Warranty:
- 18 months
- [Ics] Rated Service Breaking Capacity:
- 25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Network Frequency:
- 50/60 Hz
- Width:
- 104 mm
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Mercury Free:
- Yes
- Poles Description:
- 2P
- Eu Rohs Directive:
- Compliant with Exemptions
- Quality Labels:
- CE
- Magnetic Hold Current:
- 875 A
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Control Type:
- toggle
- Trip Unit Technology:
- thermal-magnetic
- Pollution Degree:
- 3
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Mounting Height:
- 4.5 in
- Mounting Support:
- bracket
- Product Certifications:
- UL || CSA || NOM
- Depth:
- 86 mm
- Protection Type:
- overload protection || short-circuit protection
- Utilisation Category:
- category A
- Circuit Breaker Application:
- HACR rated