- Warranty:
- 18 months
- Depth:
- 86 mm
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Continuous Current Rating:
- 0.8
- Poles Description:
- 2P
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Tightening Torque:
- 25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
- Communication Interface:
- Modbus
- Product Or Component Type:
- circuit breaker
- Mercury Free:
- Yes
- Rohs Exemption Information:
- Yes
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Utilisation Category:
- category A
- Ambient Air Temperature For Storage:
- -50-85 °C
- Trip Unit Technology:
- thermal-magnetic
- Network Frequency:
- 50/60 Hz
- Magnetic Hold Current:
- 1250 A
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Width:
- 104 mm
- Mounting Height:
- 4.5 in
- Quality Labels:
- CE
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Environmental Disclosure:
- ENVPEP1311008EN
- Eu Rohs Directive:
- Compliant
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Pollution Degree:
- 3
- Net Weight:
- 2.4 kg
- Suitability For Isolation:
- yes IEC 60947-2
- [Ics] Rated Service Breaking Capacity:
- 25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Circularity Profile:
- ENVEOLI1311008
- Ambient Air Temperature For Operation:
- -2-70 °C
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Mounting Mode:
- I-Line bracket)
- Protection Type:
- overload protection || short-circuit protection
- Control Type:
- toggle
- Product Certifications:
- UL || CSA || NOM
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Electrical Connection:
- I-Line connection, line || lugs, load
- Breaking Capacity Code:
- D
- Wire Stripping Length:
- 25 mm
- Magnetic Tripping Current:
- 2500-2500 A
- Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
- Height:
- 191 mm
- Circuit Breaker Application:
- HACR rated
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- Terminal Identifier:
- AL250JD
- Line Rated Current:
- 250-250 A
- Pvc Free:
- Yes
- Ip Degree Of Protection:
- front cover IP40
- Awg Gauge:
- AWG 3/0...350 kcmil aluminium/copper terminals
- Mounting Support:
- bracket
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Sustainable Offer Status:
- Green Premium product
- Phase Connection:
- BC