- Circuit Breaker Application:
- HACR rated
- Utilisation Category:
- category A
- Sustainable Offer Status:
- Green Premium product
- Continuous Current Rating:
- 0.8
- Rohs Exemption Information:
- Yes
- Protection Type:
- overload protection || short-circuit protection
- Local Signalling:
- ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm 1 LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
- Ambient Air Temperature For Operation:
- -2-70 °C
- Mercury Free:
- Yes
- Control Type:
- toggle
- Awg Gauge:
- AWG 3/0...350 kcmil aluminium/copper terminals
- Mounting Support:
- bracket
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Range:
- PowerPact
- Communication Interface:
- Modbus || Ethernet
- Ambient Air Temperature For Storage:
- -50-85 °C
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Electrical Connection:
- I-Line connection, line || lugs, load
- Suitability For Isolation:
- yes IEC 60947-2
- Net Weight:
- 2.4 kg
- Circularity Profile:
- ENVEOLI2206032EN
- Trip Unit Name:
- MicroLogic 3.2
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Breaking Capacity Code:
- D
- Depth:
- 86 mm
- Network Frequency:
- 50/60 Hz
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Terminal Identifier:
- AL250JD
- Environmental Disclosure:
- ENVPEP2206032EN
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- Height:
- 191 mm
- Product Or Component Type:
- circuit breaker
- Mounting Height:
- 4.5 in
- Ip Degree Of Protection:
- front cover IP40
- Wire Stripping Length:
- 25 mm
- Mounting Mode:
- I-Line bracket)
- Quality Labels:
- CE
- Width:
- 104 mm
- Poles Description:
- 3P
- Pollution Degree:
- 3 IEC 60947-1
- Pvc Free:
- Yes
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Warranty:
- 18 months
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Device Application:
- distribution
- Product Certifications:
- UL || CSA || NOM
- Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Line Rated Current:
- 250-250 A
- [Ics] Rated Service Breaking Capacity:
- 25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Tightening Torque:
- 25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
- Trip Unit Technology:
- electronic, standard, MicroLogic 3.2, LI
- Product Name:
- PowerPact J
- Phase Connection:
- BC
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Eu Rohs Directive:
- Compliant with Exemptions