- Protection Type:
- overload protection || short-circuit protection
- Circuit Breaker Application:
- HACR rated
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Wire Stripping Length:
- 25 mm
- Pvc Free:
- Yes
- Depth:
- 86 mm
- Trip Unit Technology:
- thermal-magnetic
- Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
- Net Weight:
- 2.4 kg
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Network Frequency:
- 50/60 Hz
- Continuous Current Rating:
- 0.8
- Environmental Disclosure:
- ENVPEP2206031EN
- Magnetic Hold Current:
- 1000 A
- Product Or Component Type:
- circuit breaker
- Poles Description:
- 3P
- Quality Labels:
- CE
- [Ics] Rated Service Breaking Capacity:
- 25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Ip Degree Of Protection:
- front cover IP40
- Mercury Free:
- Yes
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Sustainable Offer Status:
- Green Premium product
- Range:
- PowerPact
- Tightening Torque:
- 25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Suitability For Isolation:
- yes IEC 60947-2
- Product Name:
- PowerPact J
- Mounting Support:
- lug
- Communication Interface:
- Modbus || Ethernet
- Rohs Exemption Information:
- Yes
- Ambient Air Temperature For Operation:
- -2-70 °C
- Breaking Capacity Code:
- D
- Height:
- 191 mm
- Eu Rohs Directive:
- Compliant with Exemptions
- Mounting Mode:
- unit mount lug)
- Ambient Air Temperature For Storage:
- -50-85 °C
- Terminal Identifier:
- AL250JD
- Control Type:
- toggle
- Product Certifications:
- UL || CSA || NOM
- Device Application:
- distribution
- Circularity Profile:
- ENVEOLI2206031EN
- Awg Gauge:
- AWG 3/0...350 kcmil aluminium/copper terminals
- Pollution Degree:
- 3 IEC 60947-1
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Warranty:
- 18 months
- Utilisation Category:
- category A
- Line Rated Current:
- 200-200 A
- Width:
- 104 mm
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Electrical Connection:
- lugs, line || lugs, load
- Magnetic Tripping Current:
- 2000-2000 A
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.