Schneider Electric JDM36225 Molded Case Circuit Breaker 600V 225A
Schneider Electric
$2,730.00
PowerPacT J-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT J-Frame circuit breakers are available with either thermal magnetic or MicroLogic electronic trip protection units. This PowerPacT J-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT J-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT J circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on the line side and terminal nuts on the load side. This PowerPacT J, 225A, 3 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT J circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Width:
- 104 mm
- Product Or Component Type:
- circuit breaker
- Circuit Breaker Application:
- HACR rated
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Net Weight:
- 2.4 kg
- Protection Type:
- overload protection || short-circuit protection
- Mounting Height:
- 4.5 in
- Eu Rohs Directive:
- Compliant with Exemptions
- Continuous Current Rating:
- 0.8
- Mounting Support:
- lug
- Line Rated Current:
- 225-225 A
- Height:
- 191 mm
- Wire Stripping Length:
- 25 mm
- Mounting Mode:
- unit mount lug)
- Rohs Exemption Information:
- Yes
- Control Type:
- toggle
- Phase Connection:
- ABC
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Suitability For Isolation:
- yes IEC 60947-2
- [Ics] Rated Service Breaking Capacity:
- 25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Ambient Air Temperature For Storage:
- -50-85 °C
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Poles Description:
- 3P
- Magnetic Tripping Current:
- 2250-2250 A
- Pvc Free:
- Yes
- Range:
- PowerPact
- Circularity Profile:
- ENVEOLI2206031EN
- Environmental Disclosure:
- ENVPEP2206031EN
- Product Certifications:
- UL || CSA || NOM
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Depth:
- 86 mm
- Device Application:
- distribution
- Communication Interface:
- Modbus || Ethernet
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Product Name:
- PowerPact J
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Trip Unit Technology:
- thermal-magnetic
- Sustainable Offer Status:
- Green Premium product
- Ip Degree Of Protection:
- front cover IP40
- Ambient Air Temperature For Operation:
- -2-70 °C
- Terminal Identifier:
- AL250JD
- Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
- Utilisation Category:
- category A
- Quality Labels:
- CE
- Breaking Capacity Code:
- D
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Mercury Free:
- Yes
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Electrical Connection:
- lugs, line || terminal nut, load
- Warranty:
- 18 months
- Network Frequency:
- 50/60 Hz
- Magnetic Hold Current:
- 1125 A
- Awg Gauge:
- AWG 3/0...350 kcmil aluminium/copper terminals
- Tightening Torque:
- 25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
- Pollution Degree:
- 3 IEC 60947-1
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View