Schneider Electric JGA262251 Molded Case Circuit Breaker 600V 225A

(No reviews yet) Write a Review
SKU:
JGA262251
UPC:
7.85902E+11
Condition:
New
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Ip Degree Of Protection:
front cover IP40
Sustainable Offer Status:
Green Premium product
Network Frequency:
50/60 Hz
Product Name:
PowerPact J
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Mounting Support:
bracket
Breaking Capacity Code:
G
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Depth:
86 mm
Awg Gauge:
AWG 3/0...350 kcmil aluminium/copper terminals
Magnetic Hold Current:
1125 A
Circuit Breaker Application:
HACR rated
Electrical Connection:
I-Line connection, line || lugs, load
Ambient Air Temperature For Storage:
-50-85 °C
Width:
104 mm
Magnetic Tripping Current:
2250-2250 A
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Poles Description:
2P
Protection Type:
overload protection || short-circuit protection
Pollution Degree:
3 IEC 60947-1
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Warranty:
18 months
Phase Connection:
AB
Height:
191 mm
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Eu Rohs Directive:
Compliant with Exemptions
Device Application:
distribution
Trip Unit Technology:
thermal-magnetic
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Net Weight:
2.4 kg
Mounting Mode:
I-Line bracket)
Environmental Disclosure:
ENVPEP2206031EN
Continuous Current Rating:
0.8
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Line Rated Current:
225-225 A
Wire Stripping Length:
25 mm
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz IEC 60947-3
Mounting Height:
4.5 in
Local Signalling:
switched off (OFF) 1 trip indicator green)
Product Certifications:
UL || CSA || NOM
Quality Labels:
CE
Utilisation Category:
category A
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Circularity Profile:
ENVEOLI2206031EN
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Rohs Exemption Information:
Yes
Control Type:
toggle
Communication Interface:
Modbus || Ethernet
Suitability For Isolation:
yes IEC 60947-2
Terminal Identifier:
AL250JD
Product Or Component Type:
circuit breaker
Pvc Free:
Yes
Ambient Air Temperature For Operation:
-2-70 °C
Tightening Torque:
25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
Range:
PowerPact
Mercury Free:
Yes
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric JGA262251 Molded Case Circuit Breaker 600V 225A
  • Schneider Electric JGA262251 Molded Case Circuit Breaker 600V 225A
$5,058.00

Description

PowerPacT J-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT J-Frame circuit breakers are available with either thermal magnetic or MicroLogic electronic trip protection units. This PowerPacT J-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT J-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT J circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT J I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT J, 225A, 2 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an AB phase connection. PowerPacT J circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose