- Pvc Free:
- Yes
- Product Name:
- PowerPact J
- Line Rated Current:
- 150-150 A
- Mounting Height:
- 4.5 in
- Control Type:
- toggle
- Environmental Disclosure:
- ENVPEP2206031EN
- Mounting Mode:
- I-Line bracket)
- Phase Connection:
- ABC
- Mercury Free:
- Yes
- Poles Description:
- 3P
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Product Certifications:
- UL || CSA || NOM
- Awg Gauge:
- AWG 4...AWG 4/0 aluminium/copper terminal
- Warranty:
- 18 months
- Height:
- 191 mm
- Circularity Profile:
- ENVEOLI2206031EN
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- Wire Stripping Length:
- 25 mm
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Product Or Component Type:
- circuit breaker
- Range:
- PowerPact
- Breaking Capacity:
- 65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
- Utilisation Category:
- category A
- Magnetic Hold Current:
- 750 A
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Circuit Breaker Application:
- HACR rated
- Mounting Support:
- bracket
- Continuous Current Rating:
- 0.8
- Sustainable Offer Status:
- Green Premium product
- Ip Degree Of Protection:
- front cover IP40
- Electrical Connection:
- I-Line connection, line || lugs, load
- Width:
- 104 mm
- Communication Interface:
- Modbus || Ethernet
- Trip Unit Technology:
- thermal-magnetic
- Eu Rohs Directive:
- Compliant with Exemptions
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Pollution Degree:
- 3 IEC 60947-1
- Suitability For Isolation:
- yes IEC 60947-2
- Magnetic Tripping Current:
- 1750-1750 A
- Quality Labels:
- CE
- Ambient Air Temperature For Operation:
- -2-70 °C
- Protection Type:
- overload protection || short-circuit protection
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Terminal Identifier:
- AL175JD
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Tightening Torque:
- 25-25 N.m 25-95 mm² (AWG 4...AWG 4/0)
- Rohs Exemption Information:
- Yes
- Ambient Air Temperature For Storage:
- -50-85 °C
- Breaking Capacity Code:
- G
- Depth:
- 86 mm
- Network Frequency:
- 50/60 Hz
- Net Weight:
- 2.4 kg
- Device Application:
- distribution
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)