Schneider Electric JGL36175SA Molded Case Circuit Breaker 600V 175A

(No reviews yet) Write a Review
SKU:
JGL36175SA
UPC:
785901947196
Condition:
New
Range:
PowerPact
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Rohs Exemption Information:
Yes
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Environmental Disclosure:
ENVPEP2206031EN
Terminal Identifier:
AL175JD
Sustainable Offer Status:
Green Premium product
Awg Gauge:
AWG 4...AWG 4/0 aluminium/copper terminal
Magnetic Hold Current:
875 A
Device Application:
distribution
Continuous Current Rating:
0.8
Depth:
86 mm
Quality Labels:
CE
Phase Connection:
ABC
Poles Description:
3P
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Magnetic Tripping Current:
1750-1750 A
Product Or Component Type:
circuit breaker
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Tightening Torque:
25-25 N.m 25-95 mm² (AWG 4...AWG 4/0)
Mounting Support:
lug
Breaking Capacity Code:
G
Protection Type:
overload protection || short-circuit protection
Line Rated Current:
175-175 A
Eu Rohs Directive:
Compliant with Exemptions
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Mounting Mode:
unit mount lug)
Ip Degree Of Protection:
front cover IP40
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Mounting Height:
4.5 in
Height:
191 mm
Suitability For Isolation:
yes IEC 60947-2
Product Certifications:
UL || CSA || NOM
Ambient Air Temperature For Operation:
-2-70 °C
Net Weight:
2.4 kg
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Control Type:
toggle
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Trip Unit Technology:
thermal-magnetic
Accessory / Separate Part Type:
shunt trip 110...130 V AC compartment
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Communication Interface:
Modbus || Ethernet
Mercury Free:
Yes
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz IEC 60947-3
Wire Stripping Length:
25 mm
Utilisation Category:
category A
Product Name:
PowerPact J
Pollution Degree:
3 IEC 60947-1
Pvc Free:
Yes
Warranty:
18 months
Circuit Breaker Application:
HACR rated
Width:
104 mm
Electrical Connection:
lugs, line || lugs, load
Network Frequency:
50/60 Hz
Circularity Profile:
ENVEOLI2206031EN
Ambient Air Temperature For Storage:
-50-85 °C
Local Signalling:
switched off (OFF) 1 trip indicator green)
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Brochure:
View
Catalog:
View
Datasheet:
View
$4,496.00

Description

PowerPacT J-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT J-Frame circuit breakers are available with either thermal magnetic or MicroLogic electronic trip protection units. This PowerPacT J-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT J-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT J circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT J, 175A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. This unit includes a factory installed 120VAC shunt trip. PowerPacT J circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose