- Circuit Breaker Application:
- HACR rated
- Electrical Connection:
- lugs, line || lugs, load
- Trip Unit Technology:
- electronic, ammeter, MicroLogic 6.2 A, LSIG
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Ambient Air Temperature For Operation:
- -2-70 °C
- Wire Stripping Length:
- 25 mm
- Pvc Free:
- Yes
- Device Application:
- distribution
- Breaking Capacity Code:
- G
- Rohs Exemption Information:
- Yes
- Awg Gauge:
- AWG 3/0...350 kcmil aluminium/copper terminals
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Line Rated Current:
- 250-250 A
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Range:
- PowerPact
- Terminal Identifier:
- AL250JD
- Communication Interface:
- Modbus || Ethernet
- Network Frequency:
- 50/60 Hz
- Product Or Component Type:
- circuit breaker
- Pollution Degree:
- 3 IEC 60947-1
- Protection Type:
- overload protection || short-circuit protection
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Poles Description:
- 3P
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Sustainable Offer Status:
- Green Premium product
- Breaking Capacity:
- 65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
- Eu Rohs Directive:
- Compliant with Exemptions
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Mercury Free:
- Yes
- Width:
- 104 mm
- Suitability For Isolation:
- yes IEC 60947-2
- Depth:
- 86 mm
- Environmental Disclosure:
- ENVPEP2206032EN
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Quality Labels:
- CE
- Product Name:
- PowerPact J
- Mounting Support:
- lug
- Product Certifications:
- UL || CSA || NOM
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Warranty:
- 18 months
- Mounting Mode:
- unit mount lug)
- Continuous Current Rating:
- 1
- Tightening Torque:
- 25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
- Local Signalling:
- ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm 1 LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
- Ip Degree Of Protection:
- front cover IP40
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Trip Unit Name:
- MicroLogic 6.2 A
- Circularity Profile:
- ENVEOLI2206032EN
- Ambient Air Temperature For Storage:
- -50-85 °C
- Height:
- 191 mm
- Control Type:
- toggle
- Utilisation Category:
- category A
- Net Weight:
- 2.4 kg