- Wire Stripping Length:
- 25 mm
- Product Or Component Type:
- circuit breaker
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Protection Type:
- overload protection || short-circuit protection
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- Line Rated Current:
- 225-225 A
- Trip Unit Technology:
- thermal-magnetic
- Circuit Breaker Application:
- HACR rated
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Continuous Current Rating:
- 0.8
- Height:
- 191 mm
- Magnetic Hold Current:
- 1125 A
- Product Certifications:
- UL || CSA || NOM
- Network Frequency:
- 50/60 Hz
- Control Type:
- toggle
- Device Application:
- distribution
- Terminal Identifier:
- AL250JD
- Suitability For Isolation:
- yes IEC 60947-2
- Depth:
- 86 mm
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Rohs Exemption Information:
- Yes
- Ambient Air Temperature For Operation:
- -2-70 °C
- Phase Connection:
- AB
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Ambient Air Temperature For Storage:
- -50-85 °C
- Mercury Free:
- Yes
- Net Weight:
- 2.4 kg
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Quality Labels:
- CE
- Warranty:
- 18 months
- Ip Degree Of Protection:
- front cover IP40
- Magnetic Tripping Current:
- 2250-2250 A
- Range:
- PowerPact
- Eu Rohs Directive:
- Compliant with Exemptions
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Communication Interface:
- Modbus || Ethernet
- Electrical Connection:
- terminal nut, line || lugs, load
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Utilisation Category:
- category A
- Poles Description:
- 3P
- Mounting Mode:
- unit mount lug)
- Breaking Capacity Code:
- G
- Circularity Profile:
- ENVEOLI2206031EN
- Width:
- 104 mm
- Mounting Support:
- lug
- Pvc Free:
- Yes
- Pollution Degree:
- 3 IEC 60947-1
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Sustainable Offer Status:
- Green Premium product
- Awg Gauge:
- AWG 3/0...350 kcmil aluminium/copper terminals
- Product Name:
- PowerPact J
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Tightening Torque:
- 25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
- Mounting Height:
- 4.5 in
- Environmental Disclosure:
- ENVPEP2206031EN
- Breaking Capacity:
- 65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489