- Eu Rohs Directive:
- Compliant with Exemptions
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Rohs Exemption Information:
- Yes
- Tightening Torque:
- 25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
- Breaking Capacity Code:
- J
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Environmental Disclosure:
- ENVPEP2206031EN
- Product Certifications:
- UL || CSA || NOM
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Ip Degree Of Protection:
- front cover IP40
- Accessory / Separate Part Type:
- shunt trip 110...130 V AC compartment
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- Pvc Free:
- Yes
- Control Type:
- toggle
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Awg Gauge:
- AWG 3/0...350 kcmil aluminium/copper terminals
- Network Frequency:
- 50/60 Hz
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Continuous Current Rating:
- 0.8
- Warranty:
- 18 months
- Breaking Capacity:
- 100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
- Poles Description:
- 3P
- Quality Labels:
- CE
- Height:
- 191 mm
- Product Or Component Type:
- circuit breaker
- Line Rated Current:
- 200-200 A
- Wire Stripping Length:
- 25 mm
- Net Weight:
- 2.4 kg
- Electrical Connection:
- I-Line connection, line || lugs, load
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Magnetic Hold Current:
- 1000 A
- Mounting Support:
- bracket
- Mercury Free:
- Yes
- Ambient Air Temperature For Storage:
- -50-85 °C
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Circuit Breaker Application:
- HACR rated
- Circularity Profile:
- ENVEOLI2206031EN
- Ambient Air Temperature For Operation:
- -2-70 °C
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Terminal Identifier:
- AL250JD
- Utilisation Category:
- category A
- Depth:
- 86 mm
- Width:
- 104 mm
- Device Application:
- distribution
- Product Name:
- PowerPact J
- Suitability For Isolation:
- yes IEC 60947-2
- Range:
- PowerPact
- Mounting Height:
- 4.5 in
- Mounting Mode:
- I-Line bracket)
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Sustainable Offer Status:
- Green Premium product
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Protection Type:
- overload protection || short-circuit protection
- Trip Unit Technology:
- thermal-magnetic
- Magnetic Tripping Current:
- 2000-2000 A
- Pollution Degree:
- 3 IEC 60947-1
- Communication Interface:
- Modbus || Ethernet
- QN-QUOTE-REQUEST:
- true