Schneider Electric JJL36150SA Molded Case Circuit Breaker 600V 150A
Schneider Electric
$9,223.50
$1200 Minimum Order for Non-stock Items or $60 Addl Schneider Handling Fee Applies
PowerPacT J-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT J-Frame circuit breakers are available with either thermal magnetic or MicroLogic electronic trip protection units. This PowerPacT J-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 25kA at 600VAC. All PowerPacT J-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT J circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT J, 150A, 3 pole, circuit breaker has a breaking capacity of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80%. This unit includes a factory installed 120VAC shunt trip. PowerPacT J circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Line Rated Current:
- 150-150 A
- Continuous Current Rating:
- 0.8
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Magnetic Hold Current:
- 750 A
- Pvc Free:
- Yes
- Accessory / Separate Part Type:
- shunt trip 110...130 V AC compartment
- Trip Unit Technology:
- thermal-magnetic
- Electrical Connection:
- lugs, line || lugs, load
- Breaking Capacity Code:
- J
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Sustainable Offer Status:
- Green Premium product
- Awg Gauge:
- AWG 4...AWG 4/0 aluminium/copper terminal
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Range:
- PowerPact
- Communication Interface:
- Modbus || Ethernet
- Circuit Breaker Application:
- HACR rated
- Quality Labels:
- CE
- Mounting Height:
- 4.5 in
- Pollution Degree:
- 3 IEC 60947-1
- Eu Rohs Directive:
- Compliant
- Depth:
- 86 mm
- Mounting Support:
- lug
- Product Or Component Type:
- circuit breaker
- Mercury Free:
- Yes
- Ambient Air Temperature For Storage:
- -50-85 °C
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Poles Description:
- 3P
- Protection Type:
- overload protection || short-circuit protection
- Network Frequency:
- 50/60 Hz
- Circularity Profile:
- ENVEOLI1311008
- Tightening Torque:
- 25-25 N.m 25-95 mm² (AWG 4...AWG 4/0)
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Ip Degree Of Protection:
- front cover IP40
- Magnetic Tripping Current:
- 1750-1750 A
- Product Name:
- PowerPact J
- Terminal Identifier:
- AL175JD
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Environmental Disclosure:
- ENVPEP1311008EN
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Mounting Mode:
- unit mount lug)
- Wire Stripping Length:
- 25 mm
- Ambient Air Temperature For Operation:
- -2-70 °C
- Breaking Capacity:
- 100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Suitability For Isolation:
- yes IEC 60947-2
- Warranty:
- 18 months
- Rohs Exemption Information:
- Yes
- Width:
- 104 mm
- Utilisation Category:
- category A
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- Height:
- 191 mm
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Net Weight:
- 2.4 kg
- Product Certifications:
- UL || CSA || NOM
- Control Type:
- toggle
- Phase Connection:
- CA
- Device Application:
- distribution
- Brochure:
- View
- Catalog:
- View
- Datasheet: