Schneider Electric JJL36200T Molded Case Circuit Breaker 600V 200A
Schneider Electric
$5,432.00
PowerPacT J-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT J-Frame circuit breakers are available with either thermal magnetic or MicroLogic electronic trip protection units. This PowerPacT J-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 25kA at 600VAC. All PowerPacT J-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT J circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT J, 200A, 3 pole, circuit breaker has a breaking capacity of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80%. This unit allows field-interchangeable trip units. PowerPacT J circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Poles Description:
- 3P
- Rohs Exemption Information:
- Yes
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Ambient Air Temperature For Operation:
- -2-70 °C
- Width:
- 104 mm
- Ambient Air Temperature For Storage:
- -50-85 °C
- Warranty:
- 18 months
- Product Certifications:
- UL || CSA || NOM
- Mounting Mode:
- unit mount lug)
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- Circuit Breaker Application:
- HACR rated
- Continuous Current Rating:
- 0.8
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Pvc Free:
- Yes
- Awg Gauge:
- AWG 3/0...350 kcmil aluminium/copper terminals
- Circularity Profile:
- ENVEOLI2206031EN
- Line Rated Current:
- 200-200 A
- Height:
- 191 mm
- Wire Stripping Length:
- 25 mm
- Range:
- PowerPact
- Net Weight:
- 2.4 kg
- Ip Degree Of Protection:
- front cover IP40
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Eu Rohs Directive:
- Compliant with Exemptions
- Terminal Identifier:
- AL250JD
- Product Or Component Type:
- circuit breaker
- Breaking Capacity:
- 100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Breaking Capacity Code:
- J
- Product Name:
- PowerPact J
- Magnetic Hold Current:
- 1000 A
- Mercury Free:
- Yes
- Mounting Support:
- lug
- Network Frequency:
- 50/60 Hz
- Sustainable Offer Status:
- Green Premium product
- Quality Labels:
- CE
- Pollution Degree:
- 3 IEC 60947-1
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Trip Unit Technology:
- thermal-magnetic
- Utilisation Category:
- category A
- Communication Interface:
- Modbus || Ethernet
- Environmental Disclosure:
- ENVPEP2206031EN
- Magnetic Tripping Current:
- 2000-2000 A
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Protection Type:
- overload protection || short-circuit protection
- Depth:
- 86 mm
- Control Type:
- toggle
- Electrical Connection:
- lugs, line || lugs, load
- Device Application:
- distribution
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Tightening Torque:
- 25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
- Suitability For Isolation:
- yes IEC 60947-2
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View