- Electrical Connection:
- lugs, line || lugs, load
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Height:
- 191 mm
- Network Frequency:
- 50/60 Hz
- Ip Degree Of Protection:
- front cover IP40
- Environmental Disclosure:
- ENVPEP2206031EN
- Width:
- 104 mm
- Depth:
- 86 mm
- Awg Gauge:
- AWG 3/0...350 kcmil aluminium/copper terminals
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- Quality Labels:
- CE
- Poles Description:
- 3P
- Communication Interface:
- Modbus
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Terminal Identifier:
- AL250JD
- Rohs Exemption Information:
- Yes
- Sustainable Offer Status:
- Green Premium product
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Product Certifications:
- UL || CSA || NOM
- Wire Stripping Length:
- 25 mm
- Magnetic Hold Current:
- 1250 A
- Eu Rohs Directive:
- Compliant with Exemptions
- Mounting Support:
- lug
- Circularity Profile:
- ENVEOLI2206031EN
- Net Weight:
- 2.4 kg
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Accessory / Separate Part Type:
- shunt trip 110...130 V AC compartment
- Utilisation Category:
- category A
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Control Type:
- toggle
- Ambient Air Temperature For Operation:
- -2-70 °C
- Continuous Current Rating:
- 0.8
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Suitability For Isolation:
- yes IEC 60947-2
- Ambient Air Temperature For Storage:
- -50-85 °C
- Pvc Free:
- Yes
- Protection Type:
- overload protection || short-circuit protection
- Mercury Free:
- Yes
- Product Or Component Type:
- Motor Circuit Protector
- Breaking Capacity:
- 100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
- Magnetic Tripping Current:
- 2500-2500 A
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- [Ith] Conventional Free Air Thermal Current:
- 117-217 A
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Mounting Mode:
- unit mount lug)
- Pollution Degree:
- 3
- Warranty:
- 18 months
- Trip Unit Technology:
- thermal-magnetic
- Breaking Capacity Code:
- J
- Line Rated Current:
- 250-250 A
- Tightening Torque:
- 25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)