- Ambient Air Temperature For Storage:
- -50-85 °C
- Product Certifications:
- UL || CSA || NOM
- Warranty:
- 18 months
- Electrical Connection:
- I-Line connection, line || lugs, load
- Magnetic Hold Current:
- 1000 A
- Quality Labels:
- CE
- Width:
- 104 mm
- Pvc Free:
- Yes
- Utilisation Category:
- category A
- Network Frequency:
- 50/60 Hz
- Communication Interface:
- Modbus
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Ip Degree Of Protection:
- front cover IP40
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Continuous Current Rating:
- 0.8
- Line Rated Current:
- 200-200 A
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- Suitability For Isolation:
- yes IEC 60947-2
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Circularity Profile:
- ENVEOLI2206031EN
- Mercury Free:
- Yes
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Net Weight:
- 2.4 kg
- Mounting Support:
- bracket
- Terminal Identifier:
- AL250JD
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Control Type:
- toggle
- Eu Rohs Directive:
- Compliant with Exemptions
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- [Ics] Rated Service Breaking Capacity:
- 125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Environmental Disclosure:
- ENVPEP2206031EN
- Height:
- 191 mm
- Trip Unit Technology:
- thermal-magnetic
- Tightening Torque:
- 25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
- Product Or Component Type:
- circuit breaker
- Poles Description:
- 3P
- Breaking Capacity:
- 125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
- Mounting Height:
- 4.5 in
- Pollution Degree:
- 3
- Magnetic Tripping Current:
- 2000-2000 A
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Circuit Breaker Application:
- HACR rated
- Ambient Air Temperature For Operation:
- -2-70 °C
- Phase Connection:
- ABC
- Depth:
- 86 mm
- Awg Gauge:
- AWG 3/0...350 kcmil aluminium/copper terminals
- Protection Type:
- overload protection || short-circuit protection
- Breaking Capacity Code:
- L
- Wire Stripping Length:
- 25 mm
- Mounting Mode:
- I-Line bracket)
- Sustainable Offer Status:
- Green Premium product
- Rohs Exemption Information:
- Yes
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating