- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- [Ics] Rated Service Breaking Capacity:
- 125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Ambient Air Temperature For Storage:
- -50-85 °C
- Line Rated Current:
- 250-250 A
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Network Frequency:
- 50/60 Hz
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Pvc Free:
- Yes
- Mounting Mode:
- I-Line bracket)
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Eu Rohs Directive:
- Compliant with Exemptions
- Poles Description:
- 3P
- Circularity Profile:
- ENVEOLI2206031EN
- Communication Interface:
- Modbus
- Circuit Breaker Application:
- HACR rated
- Ip Degree Of Protection:
- front cover IP40
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Ambient Air Temperature For Operation:
- -2-70 °C
- Breaking Capacity:
- 125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
- Depth:
- 86 mm
- Suitability For Isolation:
- yes IEC 60947-2
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Net Weight:
- 2.4 kg
- Pollution Degree:
- 3
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Quality Labels:
- CE
- Width:
- 104 mm
- Mounting Height:
- 4.5 in
- Sustainable Offer Status:
- Green Premium product
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- Product Or Component Type:
- circuit breaker
- Terminal Identifier:
- AL250JD
- Mounting Support:
- bracket
- Height:
- 191 mm
- Awg Gauge:
- AWG 3/0...350 kcmil aluminium/copper terminals
- Continuous Current Rating:
- 0.8
- Utilisation Category:
- category A
- Product Certifications:
- UL || CSA || NOM
- Phase Connection:
- ABC
- Tightening Torque:
- 25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
- Control Type:
- toggle
- Magnetic Hold Current:
- 1250 A
- Trip Unit Technology:
- thermal-magnetic
- Environmental Disclosure:
- ENVPEP2206031EN
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Rohs Exemption Information:
- Yes
- Warranty:
- 18 months
- Protection Type:
- overload protection || short-circuit protection
- Mercury Free:
- Yes
- Magnetic Tripping Current:
- 2500-2500 A
- Breaking Capacity Code:
- L
- Electrical Connection:
- I-Line connection, line || lugs, load
- Wire Stripping Length:
- 25 mm