- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Eu Rohs Directive:
- Compliant with Exemptions
- Environmental Disclosure:
- ENVPEP2206032EN
- Depth:
- 86 mm
- Utilisation Category:
- category A
- Tightening Torque:
- 25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Suitability For Isolation:
- yes IEC 60947-2
- [Ics] Rated Service Breaking Capacity:
- 125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Height:
- 191 mm
- Mounting Height:
- 4.5 in
- Mounting Support:
- bracket
- Ip Degree Of Protection:
- front cover IP40
- Warranty:
- 18 months
- Terminal Identifier:
- AL250JD
- Breaking Capacity:
- 125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
- Local Signalling:
- ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm 1 LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
- Width:
- 104 mm
- Circuit Breaker Application:
- HACR rated
- Net Weight:
- 2.4 kg
- Phase Connection:
- ABC
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Continuous Current Rating:
- 0.8
- Circularity Profile:
- ENVEOLI2206032EN
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Wire Stripping Length:
- 25 mm
- Trip Unit Technology:
- electronic, standard, MicroLogic 3.2 S, LSI
- Line Rated Current:
- 250-250 A
- Pvc Free:
- Yes
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- Poles Description:
- 3P
- Ambient Air Temperature For Operation:
- -2-70 °C
- Electrical Connection:
- I-Line connection, line || lugs, load
- Network Frequency:
- 50/60 Hz
- Ambient Air Temperature For Storage:
- -50-85 °C
- Product Certifications:
- UL || CSA || NOM
- Protection Type:
- overload protection || short-circuit protection
- Mounting Mode:
- I-Line bracket)
- Sustainable Offer Status:
- Green Premium product
- Pollution Degree:
- 3
- Product Or Component Type:
- circuit breaker
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Control Type:
- toggle
- Quality Labels:
- CE
- Rohs Exemption Information:
- Yes
- Communication Interface:
- Modbus
- Awg Gauge:
- AWG 3/0...350 kcmil aluminium/copper terminals
- Trip Unit Name:
- MicroLogic 3.2 S
- Breaking Capacity Code:
- L
- Mercury Free:
- Yes