- Phase Connection:
- ABC
- Mercury Free:
- Yes
- Mounting Mode:
- I-Line bracket)
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- Suitability For Isolation:
- yes IEC 60947-2
- Utilisation Category:
- category A
- Product Or Component Type:
- circuit breaker
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Pvc Free:
- Yes
- Ambient Air Temperature For Operation:
- -2-70 °C
- Pollution Degree:
- 3
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Ambient Air Temperature For Storage:
- -50-85 °C
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Communication Interface:
- Modbus
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Height:
- 191 mm
- Electrical Connection:
- I-Line connection, line || lugs, load
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Circularity Profile:
- ENVEOLI2206032EN
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Warranty:
- 18 months
- Line Rated Current:
- 250-250 A
- Depth:
- 86 mm
- Poles Description:
- 3P
- Ip Degree Of Protection:
- front cover IP40
- Sustainable Offer Status:
- Green Premium product
- Quality Labels:
- CE
- Mounting Height:
- 4.5 in
- Wire Stripping Length:
- 25 mm
- [Ics] Rated Service Breaking Capacity:
- 125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Continuous Current Rating:
- 0.8
- Product Certifications:
- UL || CSA || NOM
- Breaking Capacity:
- 125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Mounting Support:
- bracket
- Eu Rohs Directive:
- Compliant with Exemptions
- Local Signalling:
- ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm 1 LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
- Circuit Breaker Application:
- HACR rated
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Control Type:
- toggle
- Net Weight:
- 2.4 kg
- Breaking Capacity Code:
- L
- Rohs Exemption Information:
- Yes
- Width:
- 104 mm
- Trip Unit Name:
- MicroLogic 5.2 A
- Awg Gauge:
- AWG 3/0...350 kcmil aluminium/copper terminals
- Terminal Identifier:
- AL250JD
- Trip Unit Technology:
- electronic, ammeter, MicroLogic 5.2 A, LSI
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Tightening Torque:
- 25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
- Network Frequency:
- 50/60 Hz
- Environmental Disclosure:
- ENVPEP2206032EN
- Protection Type:
- overload protection || short-circuit protection