Schneider Electric JLF36200 Molded Case Circuit Breaker 600V 200A

(No reviews yet) Write a Review
SKU:
JLF36200
UPC:
3606482046283
Condition:
New
Sustainable Offer Status:
Green Premium product
Environmental Disclosure:
ENVPEP2206031EN
Product Or Component Type:
circuit breaker
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Breaking Capacity Code:
L
Line Rated Current:
200-200 A
Suitability For Isolation:
yes IEC 60947-2
[Ics] Rated Service Breaking Capacity:
125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Terminal Identifier:
AL250JD
Communication Interface:
Modbus
Continuous Current Rating:
0.8
Pollution Degree:
3
Circuit Breaker Application:
HACR rated
Tightening Torque:
25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Depth:
86 mm
Awg Gauge:
AWG 3/0...350 kcmil aluminium/copper terminals
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz IEC 60947-3
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Wire Stripping Length:
25 mm
Mounting Support:
busbar
Ip Degree Of Protection:
front cover IP40
Utilisation Category:
category A
Network Frequency:
50/60 Hz
Eu Rohs Directive:
Compliant with Exemptions
Mounting Mode:
unit mount busbar)
Product Certifications:
UL || CSA || NOM
Electrical Connection:
busbar connection, line || busbar connection, load
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Width:
104 mm
Poles Description:
3P
Rohs Exemption Information:
Yes
Local Signalling:
switched off (OFF) 1 trip indicator green)
Magnetic Hold Current:
1000 A
Ambient Air Temperature For Operation:
-2-70 °C
Trip Unit Technology:
thermal-magnetic
Ambient Air Temperature For Storage:
-50-85 °C
Breaking Capacity:
125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Mercury Free:
Yes
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Magnetic Tripping Current:
2000-2000 A
Pvc Free:
Yes
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Control Type:
toggle
Net Weight:
2.4 kg
Protection Type:
overload protection || short-circuit protection
Height:
191 mm
Quality Labels:
CE
Warranty:
18 months
Circularity Profile:
ENVEOLI2206031EN
$10,629.00

Description

PowerPacT J-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT J-Frame circuit breakers are available with either thermal magnetic or MicroLogic electronic trip protection units. This PowerPacT J-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 50kA at 600VAC. All PowerPacT J-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT J circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has a busbar connection. This PowerPacT J, 200A, 3 pole, circuit breaker has a breaking capacity of 50kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT J circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose