- Ip Degree Of Protection:
- front cover IP40
- Warranty:
- 18 months
- Continuous Current Rating:
- 0.8
- Tightening Torque:
- 25-25 N.m 25-95 mm² (AWG 4...AWG 4/0)
- Magnetic Tripping Current:
- 1750-1750 A
- Depth:
- 86 mm
- Circularity Profile:
- ENVEOLI2206031EN
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Trip Unit Technology:
- thermal-magnetic
- Electrical Connection:
- lugs, line || lugs, load
- Product Or Component Type:
- circuit breaker
- Product Certifications:
- UL || CSA || NOM
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Pvc Free:
- Yes
- Environmental Disclosure:
- ENVPEP2206031EN
- Width:
- 104 mm
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Awg Gauge:
- AWG 4...AWG 4/0 aluminium/copper terminal
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Terminal Identifier:
- AL175JD
- Mounting Support:
- lug
- Network Frequency:
- 50/60 Hz
- Poles Description:
- 2P
- Eu Rohs Directive:
- Compliant with Exemptions
- Breaking Capacity:
- 125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- Utilisation Category:
- category A
- Net Weight:
- 2.4 kg
- Breaking Capacity Code:
- L
- Mounting Mode:
- unit mount lug)
- Sustainable Offer Status:
- Green Premium product
- Suitability For Isolation:
- yes IEC 60947-2
- Control Type:
- toggle
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Quality Labels:
- CE
- Circuit Breaker Application:
- HACR rated
- Communication Interface:
- Modbus
- Rohs Exemption Information:
- Yes
- Line Rated Current:
- 150-150 A
- Wire Stripping Length:
- 25 mm
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Ambient Air Temperature For Operation:
- -2-70 °C
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Mercury Free:
- Yes
- Magnetic Hold Current:
- 750 A
- Height:
- 191 mm
- Ambient Air Temperature For Storage:
- -50-85 °C
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Pollution Degree:
- 3
- [Ics] Rated Service Breaking Capacity:
- 125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Protection Type: