Schneider Electric JRA36225 Molded Case Circuit Breaker 600V 225A
Schneider Electric
$9,489.00
$1200 Minimum Order for Non-stock Items or $60 Addl Schneider Handling Fee Applies
PowerPacT J-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT J-Frame circuit breakers are available with either thermal magnetic or MicroLogic electronic trip protection units. This PowerPacT J-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 100kA at 600VAC. All PowerPacT J-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT J circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT J I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT J, 225A, 3 pole, circuit breaker has a breaking capacity of 100kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT J circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Protection Type:
- overload protection || short-circuit protection
- Magnetic Tripping Current:
- 2250-2250 A
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Quality Labels:
- CE
- Terminal Identifier:
- AL250JD
- Wire Stripping Length:
- 25 mm
- Circuit Breaker Application:
- HACR rated
- Height:
- 191 mm
- Line Rated Current:
- 225-225 A
- Control Type:
- toggle
- Ip Degree Of Protection:
- front cover IP40
- Tightening Torque:
- 25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
- Suitability For Isolation:
- yes IEC 60947-2
- [Ics] Rated Service Breaking Capacity:
- 150 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 125 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 75 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 690 V AC 50/60 Hz IEC 60947-2
- Awg Gauge:
- AWG 3/0...350 kcmil aluminium/copper terminals
- Environmental Disclosure:
- ENVPEP2206031EN
- Net Weight:
- 2.4 kg
- Sustainable Offer Status:
- Green Premium product
- Network Frequency:
- 50/60 Hz
- Width:
- 104 mm
- Product Or Component Type:
- circuit breaker
- Magnetic Hold Current:
- 1125 A
- Ambient Air Temperature For Storage:
- -50-85 °C
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Breaking Capacity:
- 200 kA 240 V AC 50/60 Hz UL 489 || 200 kA 480 V AC 50/60 Hz UL 489 || 100 kA 600 V AC 50/60 Hz UL 489
- Breaking Capacity Code:
- R
- Pollution Degree:
- 3
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Trip Unit Technology:
- thermal-magnetic
- Electrical Connection:
- I-Line connection, line || lugs, load
- Continuous Current Rating:
- 0.8
- Poles Description:
- 3P
- Eu Rohs Directive:
- Compliant with Exemptions
- Depth:
- 86 mm
- Rohs Exemption Information:
- Yes
- Utilisation Category:
- category A
- Circularity Profile:
- ENVEOLI2206031EN
- Phase Connection:
- ABC
- Mounting Mode:
- I-Line bracket)
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Communication Interface:
- Modbus
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- Ambient Air Temperature For Operation:
- -2-70 °C
- Mounting Support:
- bracket
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Pvc Free:
- Yes
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Mounting Height:
- 4.5 in
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Product Certifications:
- UL || CSA || NOM
- Mercury Free:
- Yes
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View