Schneider Electric K1D011B K1 Contact Block
Schneider Electric
$132.00
Cam switch body for BCD encoded withoutput switch, Harmony K, 22mm, plastic, 1 pole, 11 positions, 45°, 12A
- [Ui] Rated Insulation Voltage:
- 690 V 3)IEC 60947-1
- Bezel Material:
- plastic
- Reach Free Of Svhc:
- Yes
- Switching Angle:
- 30 °
- Product Certifications:
- CSA 240 V 1 hp 1 phase || CSA 240 V 3 hp 3 phase 2 || UL 240 V 1 hp 3 phase || UL 240 V 0.33 hp 1 phase 2
- Vibration Resistance:
- 5 gn 10-150 Hz)IEC 68-2-6
- Toxic Heavy Metal Free:
- Yes
- Environmental Disclosure:
- ENVPEP071103EN_V1
- Mounting Location:
- front
- Contact Operation:
- slow-break
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other repr
- Ambient Air Temperature For Operation:
- -25-55 °C
- Electrical Durability:
- 1000000 cycles AC-15 || 1000000 cycles AC-21 || 500000 cycles AC-23 || 500000 cycles AC-3
- Off Position:
- with Off position
- Rohs Exemption Information:
- Yes
- Component Name:
- K1
- Number Of Decimal:
- 11
- Positive Opening:
- with
- Mercury Free:
- Yes
- Standards:
- IEC 60947-3 power circuit || IEC 60947-5-1 control circuit || CENELEC EN 50013
- Product Or Component Type:
- cam switch body
- Short-Circuit Protection:
- 16 A cartridge fuse gG
- Electrical Connection:
- captive screw clamp terminals flexible 2 x 1.5 mm² || captive screw clamp terminals solid 1 x 2.5 mm²
- China Rohs Regulation:
- X
- Short-Circuit Current:
- 10000 A
- Fixing Mode:
- Ã 22 mm hole
- Rated Operational Power In W:
- 10500 W AC-21, 500 - 660 V 3 phase IEC 947-3 || 1100 W AC-3, 230 V 3 phase IEC 947-3 || 1500 W AC-23A, 230 V 3 phase IEC 947-3 || 1500 W AC-3, 400 V 1 phase IEC 947-3 || 1500 W AC-3, 400 V 3 phase IEC 947-3 || 1500 W AC-3, 500 V 3 phase IEC 947-3 ||
- [Ie] Rated Operational Current Ac:
- 1.8 A 690 V AC-3 3 phase IEC 947-3 || 2.8 A 500 V AC-3 3 phase IEC 947-3 || 2.8 A 690 V AC-23A 3 phase IEC 947-3 || 3.3 A 400 V AC-3 3 phase IEC 947-3 || 3.8 A 500 V AC-23A 3 phase IEC 947-3 || 4.6 A 230 V AC-3 3 phase IEC 947-3 || 4.8 A 400 V AC-23A
- Sub-Assembly Composition:
- contact blocks + fixing plate
- Warranty:
- 18 months
- Net Weight:
- 0.11 kg
- [Ithe] Conventional Enclosed Thermal Current:
- 0.416666666666667
- Circularity Profile:
- N/A
- Shock Resistance:
- 30 gn IEC 68-2-27
- Sustainable Offer Status:
- Green Premium product
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Switching Positions:
- right: 0°-30°-60°-90°-120°-150°-180°-210°-240°-270°-300°-330°
- Cam Switch Function:
- BCD encoded output switch
- Overvoltage Category:
- class II IEC 536 || class II NF C 20-030
- Protective Treatment:
- TC
- Ambient Air Temperature For Storage:
- -40-70 °C
- Mechanical Durability:
- 1000000 cycles
- [Ith] Conventional Free Air Thermal Current:
- 0
- Maximum Operating Rate:
- 2.5 cyc/mn AC-21 || 2.5 cyc/mn AC-23 || 2.5 cyc/mn AC-3 || 8.333 cyc/mn AC-15
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Range Of Product:
- Harmony K
- [Uimp] Rated Impulse Withstand Voltage:
- 4 kV in isolating function || 6 kV IEC 947-1
- Datasheet: