Schneider Electric LGF36400U31X Molded Case Circuit Breaker 600V 600A

(No reviews yet) Write a Review
SKU:
LGF36400U31X
UPC:
785901521785
Condition:
New
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Pvc Free:
Yes
Depth:
110 mm
Ambient Air Temperature For Operation:
-2-70 °C
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Communication Interface:
Modbus || Ethernet
Tightening Torque:
50-50 N.m 70-240 mm² (AWG 2/0...500 kcmil)
Mercury Free:
Yes
Sustainable Offer Status:
Green Premium product
Long Time Pick-Up Adjustment Range:
0.25...1 x In
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Mounting Mode:
unit mount busbar)
Environmental Disclosure:
ENVPEP2206029EN
Protection Technology:
current limiter
Suitability For Isolation:
yes IEC 60947-2
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Electrical Connection:
busbar connection, line || busbar connection, load
Breaking Capacity Code:
G
Terminal Identifier:
AL600LS52K3
Product Certifications:
UL || CSA || NOM
Poles Description:
3P
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Eu Rohs Directive:
Compliant with Exemptions
Ambient Air Temperature For Storage:
-50-85 °C
Trip Unit Technology:
electronic, standard, MicroLogic 3.3, LI
Control Type:
toggle
Circuit Breaker Application:
HACR rated
Network Frequency:
50/60 Hz
Product Or Component Type:
circuit breaker
Warranty:
18 months
Ip Degree Of Protection:
front cover IP40
Width:
140 mm
Color:
Black
Trip Unit Name:
MicroLogic 3.3
Circularity Profile:
ENVEOLI2206029EN
Line Rated Current:
400-400 A
Utilisation Category:
category A
Mounting Support:
busbar
Awg Gauge:
2 x AWG 2/0...500 kcmil aluminium/copper
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Wire Stripping Length:
31 mm || 61 mm
Device Short Name:
L-Frame
Net Weight:
6.2 kg
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Device Application:
distribution
Height:
340 mm
Product Name:
PowerPact L
Range:
PowerPact
Rohs Exemption Information:
Yes
Local Signalling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
Pollution Degree:
3 IEC 60947-1
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz IEC 60947-3
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Continuous Current Rating:
0.8
Brochure:
View
Catalog:
View
Datasheet:
View
$5,081.00

Description

PowerPacT L-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT L-Frame circuit breakers are available with electronic trip units. All PowerPacT L-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT L circuit breakers are available in 3 and 4-pole unit mount, I-Line, and drawout constructions. This PowerPacT L, 400A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker provides MicroLogic Standard with a 3.3 trip unit and an LI function. This unit has a busbar connection. This circuit breaker has a continuous current rating of 80%. This circuit breaker has a continuous current rating of 80%. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose