Schneider Electric LGF36600U31X Molded Case Circuit Breaker 480V 400A

(No reviews yet) Write a Review
SKU:
LGF36600U31X
UPC:
785901486787
Condition:
New
Trip Unit Name:
MicroLogic 3.3
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Control Type:
toggle
Line Rated Current:
600-600 A
Ip Degree Of Protection:
front cover IP40
Product Certifications:
UL || CSA || NOM
Circularity Profile:
ENVEOLI2206029EN
Terminal Identifier:
AL600LS52K3
Device Application:
distribution
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Wire Stripping Length:
31 mm || 61 mm
Width:
140 mm
Color:
Black
Device Short Name:
L-Frame
Range:
PowerPact
Eu Rohs Directive:
Compliant with Exemptions
Product Name:
PowerPact L
Suitability For Isolation:
yes IEC 60947-2
Circuit Breaker Application:
HACR rated
Pollution Degree:
3 IEC 60947-1
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Trip Unit Technology:
electronic, standard, MicroLogic 3.3, LI
Sustainable Offer Status:
Green Premium product
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Network Frequency:
50/60 Hz
Mounting Mode:
unit mount busbar)
Continuous Current Rating:
0.8
Poles Description:
3P
Local Signalling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
Depth:
110 mm
Breaking Capacity Code:
G
Rohs Exemption Information:
Yes
Height:
340 mm
Ambient Air Temperature For Storage:
-50-85 °C
Net Weight:
6.2 kg
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Product Or Component Type:
circuit breaker
Warranty:
18 months
Communication Interface:
Modbus || Ethernet
Awg Gauge:
2 x AWG 2/0...500 kcmil aluminium/copper
Electrical Connection:
busbar connection, line || busbar connection, load
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Pvc Free:
Yes
Tightening Torque:
50-50 N.m 70-240 mm² (AWG 2/0...500 kcmil)
Utilisation Category:
category A
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz IEC 60947-3
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Ambient Air Temperature For Operation:
-2-70 °C
Mercury Free:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Mounting Support:
busbar
Environmental Disclosure:
ENVPEP2206029EN
Brochure:
View
Catalog:
View
Datasheet:
View
$7,484.00

Description

PowerPacT L-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT L-Frame circuit breakers are available with electronic trip units. All PowerPacT L-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT L circuit breakers are available in 3 and 4-pole unit mount, I-Line, and drawout constructions. This PowerPacT L, 600A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker provides MicroLogic Standard with a 3.3 trip unit and an LI function. This unit has a busbar connection. This circuit breaker has a continuous current rating of 80%. This circuit breaker has a continuous current rating of 80%. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose