- Poles Description:
- 3P
- Product Name:
- PowerPact L
- Control Type:
- toggle
- Device Application:
- distribution
- Mounting Support:
- lug
- Product Or Component Type:
- circuit breaker
- Ambient Air Temperature For Storage:
- -50-85 °C
- Line Rated Current:
- 400-400 A
- Tightening Torque:
- 50-50 N.m 70-240 mm² (AWG 2/0...500 kcmil)
- Communication Interface:
- Modbus || Ethernet
- Breaking Capacity Code:
- G
- Ip Degree Of Protection:
- front cover IP40
- Color:
- Black
- Mercury Free:
- Yes
- Sustainable Offer Status:
- Green Premium product
- Breaking Capacity:
- 65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
- Network Frequency:
- 50/60 Hz
- Awg Gauge:
- 2 x AWG 2/0...500 kcmil aluminium/copper
- Terminal Identifier:
- AL600LS52K3
- Mounting Mode:
- unit mount lug)
- Local Signalling:
- ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
- Height:
- 340 mm
- Wire Stripping Length:
- 31 mm || 61 mm
- Warranty:
- 18 months
- Circuit Breaker Application:
- HACR rated
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Environmental Disclosure:
- ENVPEP2206029EN
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Circularity Profile:
- ENVEOLI2206029EN
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- Utilisation Category:
- category A
- Continuous Current Rating:
- 0.8
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Product Certifications:
- UL || CSA || NOM
- Electrical Connection:
- lugs, line || lugs, load
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Range:
- PowerPact
- Net Weight:
- 6.2 kg
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Suitability For Isolation:
- yes IEC 60947-2
- Eu Rohs Directive:
- Compliant with Exemptions
- Trip Unit Name:
- MicroLogic 6.3 A
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Ambient Air Temperature For Operation:
- -2-70 °C
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Pollution Degree:
- 3 IEC 60947-1
- Trip Unit Technology:
- electronic, ammeter, MicroLogic 6.3 A, LSIG
- Width:
- 140 mm
- Depth:
- 110 mm
- Pvc Free:
- Yes
- Rohs Exemption Information:
- Yes
- Device Short Name:
- L-Frame
- QN-QUOTE-REQUEST:
- true