- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Mercury Free:
- Yes
- Suitability For Isolation:
- yes IEC 60947-2
- Width:
- 140 mm
- Ambient Air Temperature For Storage:
- -50-85 °C
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Tightening Torque:
- 50-50 N.m 70-240 mm² (AWG 2/0...500 kcmil)
- Mounting Support:
- lug
- Range:
- PowerPact
- Height:
- 340 mm
- Depth:
- 110 mm
- Circuit Breaker Application:
- HACR rated
- Network Frequency:
- 50/60 Hz
- Warranty:
- 18 months
- Product Or Component Type:
- circuit breaker
- Continuous Current Rating:
- 0.8
- Pvc Free:
- Yes
- Breaking Capacity Code:
- G
- Breaking Capacity:
- 65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
- Color:
- Black
- Circularity Profile:
- ENVEOLI2206029EN
- Sustainable Offer Status:
- Green Premium product
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Trip Unit Name:
- MicroLogic 3.3 S
- Device Short Name:
- L-Frame
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Awg Gauge:
- 2 x AWG 2/0...500 kcmil aluminium/copper
- Poles Description:
- 3P
- Ip Degree Of Protection:
- front cover IP40
- Net Weight:
- 6.2 kg
- Terminal Identifier:
- AL600LS52K3
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Product Name:
- PowerPact L
- Communication Interface:
- Modbus || Ethernet
- Environmental Disclosure:
- ENVPEP2206029EN
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Line Rated Current:
- 400-400 A
- Mounting Mode:
- unit mount lug)
- Control Type:
- toggle
- Wire Stripping Length:
- 31 mm || 61 mm
- Local Signalling:
- ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Ambient Air Temperature For Operation:
- -2-70 °C
- Electrical Connection:
- terminal nut, line || lugs, load
- Rohs Exemption Information:
- Yes
- Trip Unit Technology:
- electronic, standard, MicroLogic 3.3 S, LSI
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- Pollution Degree:
- 3 IEC 60947-1
- Product Certifications:
- UL || CSA || NOM
- Eu Rohs Directive:
- Compliant with Exemptions
- Device Application:
- distribution
- Utilisation Category:
- category A
- QN-QUOTE-REQUEST:
- true