- Awg Gauge:
- 2 x AWG 2/0...500 kcmil aluminium/copper
- Electrical Connection:
- busbar connection, line || busbar connection, load
- Circularity Profile:
- ENVEOLI2206029EN
- Breaking Capacity Code:
- J
- Height:
- 340 mm
- Breaking Capacity:
- 100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
- Mercury Free:
- Yes
- Wire Stripping Length:
- 31 mm || 61 mm
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Suitability For Isolation:
- yes IEC 60947-2
- Color:
- Black
- Control Type:
- toggle
- Depth:
- 110 mm
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Local Signalling:
- ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
- Rohs Exemption Information:
- Yes
- Circuit Breaker Application:
- HACR rated
- Trip Unit Name:
- MicroLogic 3.3
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Environmental Disclosure:
- ENVPEP2206029EN
- Ambient Air Temperature For Storage:
- -50-85 °C
- Product Or Component Type:
- circuit breaker
- Protection Technology:
- current limiter
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Network Frequency:
- 50/60 Hz
- Mounting Support:
- busbar
- Eu Rohs Directive:
- Compliant with Exemptions
- Product Certifications:
- UL || CSA || NOM
- Continuous Current Rating:
- 1
- Line Rated Current:
- 400-400 A
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Width:
- 140 mm
- Device Short Name:
- L-Frame
- Device Application:
- distribution
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Poles Description:
- 3P
- Product Name:
- PowerPact L
- Ip Degree Of Protection:
- front cover IP40
- Ambient Air Temperature For Operation:
- -2-70 °C
- Trip Unit Technology:
- electronic, standard, MicroLogic 3.3, LI
- Pollution Degree:
- 3 IEC 60947-1
- Terminal Identifier:
- AL600LS52K3
- Range:
- PowerPact
- Net Weight:
- 6.2 kg
- Warranty:
- 18 months
- Mounting Mode:
- unit mount busbar)
- Utilisation Category:
- category A
- Tightening Torque:
- 50-50 N.m 70-240 mm² (AWG 2/0...500 kcmil)
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Communication Interface:
- Modbus || Ethernet
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Pvc Free:
- Yes
- Sustainable Offer Status:
- Green Premium product
- QN-QUOTE-REQUEST:
- true