Schneider Electric LU2B32B Reverser 32A 24V Ac
Schneider Electric
$720.00
TeSys U standard reversing power base, 3 poles (3NO), rated 32A/690V, to be completed with a control unit LUC to form a TeSys U reversing starter controller, for 3-phase motor applications up to 15kW@400V. Base composed of power contacts, control coil, rotary handle, with a modular design for additional modules to form a "all in one" reversing starter controller with basic or advanced protection and control functions. It is equipped with a reverser module LU2MB0B to be supplied with 24V AC, auxiliary signaling contacts (1NO+1NC), a control terminal block, blanking shutters covering the empty cavities. It provides a high breaking capacity Icu 50kA@400V, start-stop control guaranteed for 3600 cycles/hour. Very compact (45mm width), DIN-rail mounting and screw fixing, with a padlockable rotary handle. Certified when used in conjunction with a LUC control unit (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
- Product Certifications:
- CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine
- Height:
- 224 mm
- Heat Dissipation:
- 3-3 W control circuit with LUCA, LUCB, LUCC, LUCD || 1.8-1.8 W control circuit with LUCM
- Immunity To Microbreaks:
- 3 ms control circuit
- Maximum Operating Rate:
- 3600 cyc/h
- [Ics] Rated Service Breaking Capacity:
- 50 kA 230 V || 50 kA 440 V || 10 kA 500 V || 4 kA 690 V
- Ip Degree Of Protection:
- IP20 IEC 60947-1 front panel and wired terminals) || IP20 IEC 60947-1 other faces) || IP40 IEC 60947-1 front panel outside connection zone)
- Auxiliary Contacts Type:
- linked contacts 1 NO + 1 NC) IEC 60947-4-1 || mirror contact 1 NC) IEC 60947-1
- Safe Separation Of Circuit:
- 400 V SELV between the control and auxiliary circuits IEC 60947-1 appendix N || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 appendix N
- Device Application:
- motor control || motor protection
- Operating Altitude:
- 6561.68 ft (2000 m)
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Vibration Resistance:
- 2 gn 5-300 Hz) power poles open IEC 60068-2-27 || 4 gn 5-300 Hz) power poles closed IEC 60068-2-27
- Standards:
- EN 60947-6-2 || IEC 60947-6-2 || UL 60947-4-1, with phase barrier || CSA C22.2 No 60947-4-1, with phase barrier
- [Ie] Rated Operational Current:
- 28.5 A <= 440 V || 23 A 500 V || 21 A 690 V
- Tightening Torque:
- control circuit 0.8-1.2 N.m flat 5 mm || control circuit 0.8-1.2 N.m Philips no 1 5 mm || power circuit 1.9-2.5 N.m flat 6 mm || power circuit 1.9-2.5 N.m Philips No 2 6 mm || power circuit 1.9-2.5 N.m pozidriv No 2 6 mm
- Poles Description:
- 3P
- Control Circuit Voltage Limits:
- 14.5 V AC drop-out || 20...26.5 V AC in operation
- Suitability For Isolation:
- yes
- Resistance To Fast Transients:
- 2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4
- Mechanical Durability:
- 15 Mcycles
- Ambient Air Temperature For Operation:
- -25-60 °C with LUCM || -25-70 °C with LUCA, LUCB, LUCC, LUCD
- Immunity To Radioelectric Fields:
- 10 V IEC 61000-4-6
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
- Resistance To Radiated Fields:
- 10 V/m 3 IEC 61000-4-3
- Width:
- 45 mm
- Connections - Terminals:
- control circuit screw clamp terminals 1 0.34-1.5 mm² flexible with cable end || control circuit screw clamp terminals 1 0.75-1.5 mm² flexible without cable end || control circuit screw clamp terminals 1 0.75-1.5 mm² rigid || control circuit screw
- Typical Current Consumption:
- 2360 mA 24 V AC I maximum while closing
- Operating Time:
- 150 ms with change of direction power circuit || 35 ms opening control circuit || 70 ms closing control circuit || 75 ms without change of direction power circuit
- Non-Dissipating Shock Wave:
- 1 kV serial mode IEC 60947-6-2 || 2 kV common mode IEC 60947-6-2
- Compatibility Code:
- LU2B
- Product Compatibility:
- control unit LUC.X6B || control unit LUC.1XB || control unit LUC.05B || control unit LUC.12B || control unit LUC.18B || control unit LUC.32B
- Fixing Mode:
- clipped DIN rail) || screw-fixed plate)
- Range:
- TeSys
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Product Or Component Type:
- reversing power base
- Eu Rohs Directive:
- Compliant with Exemptions
- Rohs Exemption Information:
- Yes
- Net Weight:
- 1.27 kg
- Immunity To Voltage Dips:
- 70 % / 500 ms IEC 61000-4-11
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Product Name:
- TeSys Ultra
- Resistance To Electrostatic Discharge:
- 8 kV 3 in open air IEC 61000-4-2 || 8 kV 4 on contact IEC 61000-4-2
- Warranty:
- 18 months
- [Ui] Rated Insulation Voltage:
- 690 V IEC 60947-6-2 3) || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
- Inrush Restraint Duration:
- 25 ms AC 50/60 Hz
- Device Short Name:
- LU2B
- [Ith] Conventional Free Air Thermal Current:
- 32 A
- Shock Resistance:
- 10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27
- Utilisation Category:
- AC-43 || AC-44 || AC-41
- Depth:
- 126 mm
- [Uc] Control Circuit Voltage:
- 24 V AC 50/60 Hz
- Mercury Free:
- Yes
- Ambient Air Temperature For Storage:
- -40-85 °C
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kVIEC 60947-6-2
- Network Frequency:
- 40...60 Hz
- [Ue] Rated Operational Voltage:
- 690 V AC power circuit
- Fire Resistance:
- 960 °C parts supporting live components IEC 60695-2-12 || 650 °C IEC 60695-2-12
- Protective Treatment:
- TH IEC 60068
- Datasheet:
- View