This Multi9 C60L is a low voltage miniature circuit breaker (MCB). It is a 1P circuit breaker with 1 protected pole, 10A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 3kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. Its fast closing mechanism, overvolatge resistance and high performance limitation improve its service life. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The operating frequency is 50Hz or 60Hz. The product can be clipped on a DIN rail. Its width is 2 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The product colour is light grey (RAL7035). The dimensions are (W) 18mm x (H) 81mm x (D) 72mm. The weight is 0.12kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
- Provision For Padlocking:
- padlockable
- Mounting Support:
- DIN rail
- Trip Unit Technology:
- thermal-magnetic
- Ip Degree Of Protection:
- IP20 conforming to IEC 60529 || IP40 (modular enclosure) conforming to IEC 60529
- [Ui] Rated Insulation Voltage:
- 500 V AC 50/60 Hz EN/IEC 60947-2
- Device Short Name:
- C60L
- Line Rated Current:
- 10 A 50 °C EN/IEC 60947-2
- Height:
- 81 mm
- 9 Mm Pitches:
- 2
- Curve Code:
- C
- Breaking Capacity:
- 25 kA Icu <= 72 V DC EN/IEC 60947-2 || 3 kA Icu 415 V AC 50/60 Hz between phase and neutral EN/IEC 60947-2 || 25 kA Icu 240 V AC 50/60 Hz between phase and neutral EN/IEC 60947-2
- Tropicalisation:
- 2 IEC 60068-1
- Environmental Disclosure:
- ENVPEP1304004EN
- Tightening Torque:
- 2-2 N.m top or bottom
- Suitability For Isolation:
- yes EN/IEC 60947-2
- Contact Position Indicator:
- yes
- Circularity Profile:
- N/A
- Sustainable Offer Status:
- Green Premium product
- Magnetic Tripping Limit:
- 8.5 x In +/- 20 % AC || 12 x In +/- 20 % DC
- Network Frequency:
- 50/60 Hz
- Standards:
- EN/IEC 60947-2
- Electrical Durability:
- 10000 cycles
- Earth-Leakage Protection:
- separate block
- Pollution Degree:
- 3 EN/IEC 60947-2
- [Ics] Rated Service Breaking Capacity:
- 1.5 kA 50 % EN/IEC 60947-2 - 415 V AC 50/60 Hz || 12.5 kA 50 % EN/IEC 60947-2 - 240 V AC 50/60 Hz || 25 kA 100 % EN/IEC 60947-2 - <= 72 V DC
- Local Signalling:
- ON/OFF indication
- Poles Description:
- 1P
- Relative Humidity:
- 95-95 % 55-55 °C
- Depth:
- 72 mm
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kVEN/IEC 60947-2
- Halogen Content Performance:
- Halogen free plastic parts & cables product
- Mechanical Durability:
- 20000 cycles
- Rohs Exemption Information:
- Yes
- Overvoltage Category:
- IV
- Number Of Protected Poles:
- 1
- Heat Dissipation:
- 1.8-1.8 W 240 V - 10 A
- Net Weight:
- 0.12 kg
- Limitation Class:
- 3
- Network Type:
- AC || DC
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Device Application:
- distribution
- Product Name:
- Multi9 C60
- Width:
- 18 mm
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Utilisation Category:
- category A EN/IEC 60947-2
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Range:
- Multi9
- Mounting Mode:
- clip-on
- Ambient Air Temperature For Operation:
- -30-70 °C
- Product Certifications:
- EAC || CCC
- Eu Rohs Directive:
- Compliant with Exemptions
- Color:
- Gray
- [Ue] Rated Operational Voltage:
- 240 V AC 50/60 Hz between phase and neutral || 415 V AC 50/60 Hz between phase and neutral || <= 72 V DC
- Wire Stripping Length:
- 14 mm for top or bottom connection
- Ambient Air Temperature For Storage:
- -40-80 °C
- Product Or Component Type:
- miniature circuit-breaker
- Connections - Terminals:
- tunnel type terminal top or bottom) 1-25 mm² - rigid || tunnel type terminal top or bottom) 1-25 mm² - flexible || tunnel type terminal top or bottom) 1-25 mm² - flexible with ferrule
- Control Type:
- toggle
- Mercury Free:
- Yes
- Brochure:
- View
- Datasheet:
- View