Schneider Electric M9F21340 Multi9 C60Sp 3P B 40A 5Ka 480Y/277V Mcb
Schneider Electric
$324.00
This Multi9 C60SP is a low voltage miniature circuit breaker (MCB). It is a 3P circuit breaker with 3 protected poles, 40A rated current and B tripping curve. The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard and 10kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. Its width is 6 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 54mm x (H) 81mm x (D) 72mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 80°C.
- Curve Code:
- B
- Halogen Content Performance:
- Halogen free product
- Product Certifications:
- IEC || CCC || UR || CSA
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Ip Degree Of Protection:
- IP20 conforming to IEC 60529 || IP40 (modular enclosure) conforming to IEC 60529
- Provision For Padlocking:
- padlockable
- Tropicalisation:
- 2 IEC 60068-1
- Ambient Air Temperature For Operation:
- -30-70 °C
- Circularity Profile:
- N/A
- Local Signalling:
- ON/OFF indication
- Relative Humidity:
- 95-95 % 55-55 °C
- Wire Stripping Length:
- 14 mm for top or bottom connection
- Breaking Capacity:
- 10 kA AIR 240 V AC UL 1077 || 10 kA AIR 240 V AC CSA C22.2 No 235 || 6 kA Icu 440 V AC EN/IEC 60947-2 || 10 kA Icu 415 V AC EN/IEC 60947-2 || 20 kA Icu 240 V AC EN/IEC 60947-2 || 6 kA Icu 440 V AC GB 14048.2 || 10 kA Icu 415 V AC GB 14048.2 || 20 kA
- [Ui] Rated Insulation Voltage:
- 500 V AC EN/IEC 60947-2
- Product Name:
- Multi9 C60
- Poles Description:
- 3P
- Environmental Disclosure:
- ENVPEP1304004EN
- Operating Altitude:
- 0...6561.68 ft (0...2000 m)
- Product Or Component Type:
- miniature circuit-breaker
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Device Short Name:
- C60SP
- Color:
- Gray
- Sustainable Offer Status:
- Green Premium product
- Rohs Exemption Information:
- Yes
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kVEN/IEC 60947-2
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Mercury Free:
- Yes
- 9 Mm Pitches:
- 6
- Standards:
- EN/IEC 60947-2 || GB 14048.2 || UL 1077 || CSA C22.2 No 235
- Suitability For Isolation:
- yes EN/IEC 60947-2
- Contact Position Indicator:
- yes
- Trip Unit Technology:
- thermal-magnetic
- Mechanical Durability:
- 20000 cycles
- Depth:
- 72 mm
- [Ics] Rated Service Breaking Capacity:
- 4.5 kA 75 % EN/IEC 60947-2 - 440 V AC || 7.5 kA 75 % EN/IEC 60947-2 - 415 V AC || 15 kA 75 % EN/IEC 60947-2 - 240 V AC || 4.5 kA 75 % GB 14048.2 - 440 V AC || 7.5 kA 75 % GB 14048.2 - 415 V AC || 15 kA 75 % GB 14048.2 - 240 V AC
- Electrical Durability:
- 10000 cycles
- Range:
- Multi9
- Eu Rohs Directive:
- Compliant with Exemptions
- Network Type:
- AC
- Mounting Support:
- DIN rail
- Device Application:
- distribution
- Tightening Torque:
- 3.5-3.5 N.m top or bottom
- Width:
- 54 mm
- Height:
- 81 mm
- Pollution Degree:
- 3 EN/IEC 60947-2
- [Ue] Rated Operational Voltage:
- 240 V AC 50/60 Hz || 415 V AC 50/60 Hz || 440 V AC 50/60 Hz
- Mounting Mode:
- clip-on
- Earth-Leakage Protection:
- without
- Magnetic Tripping Limit:
- 4 x In +/- 20 % AC
- Number Of Protected Poles:
- 3
- Connections - Terminals:
- tunnel type terminal top or bottom) 1-35 mm² AWG 18...AWG 2) - rigid || tunnel type terminal top or bottom) 1-25 mm² AWG 18...AWG 3) - flexible with ferrule || tunnel type terminal top or bottom) 1-25 mm² AWG 18...AWG 3) - flexible
- Control Type:
- toggle
- Line Rated Current:
- 40 A 25 °C EN/IEC 60947-2
- Ambient Air Temperature For Storage:
- -40-80 °C
- Brochure:
- View
- Datasheet:
- View