Schneider Electric M9P22725 Multi9 N40N 3P-N 25A C 10Ka 415V Mcb
Schneider Electric
$837.00
This Multi9 N40N is a low voltage miniature circuit breaker (MCB). It is a 3P+N circuit breaker with 3 protected poles, 25A rated current and C tripping curve. The Icu rated short circuit breaking capacity is up to 10kA at 415VAC conforming to EN/IEC 60898-1 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. Its fast closing mechanism, overvolatge resistance and high performance limitation improve its service life. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 415VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. The operating frequency is 50Hz or 60Hz. The product can be clipped on a DIN rail. Its width is 6 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 54mm x (H) 81mm x (D) 78mm. The weight is 0.322kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -25°C to 70°C. The storage temperature is -40°C to 70°C.
- Product Name:
- Multi9 N40
- Halogen Content Performance:
- Halogen free product
- Network Frequency:
- 50/60 Hz
- Ambient Air Temperature For Operation:
- -25-70 °C
- Environmental Disclosure:
- ENVPEP100611EN
- Sustainable Offer Status:
- Green Premium product
- Suitability For Isolation:
- yes EN/IEC 60947-2
- Relative Humidity:
- 95-95 % 55-55 °C
- Eu Rohs Directive:
- Compliant with Exemptions
- 9 Mm Pitches:
- 6
- Magnetic Tripping Limit:
- 8.5 x In +/- 20 % AC
- Number Of Protected Poles:
- 3
- Ip Degree Of Protection:
- IP20 conforming to IEC 60529 || IP40 (modular enclosure) conforming to IEC 60529
- [Ue] Rated Operational Voltage:
- 415 V AC 50/60 Hz between phases
- Depth:
- 78 mm
- Local Signalling:
- ON/OFF indication
- Rohs Exemption Information:
- Yes
- Limitation Class:
- 3 EN/IEC 60947-2
- Control Type:
- toggle
- Device Short Name:
- N40N
- Product Or Component Type:
- miniature circuit-breaker
- Color:
- Gray
- Mounting Mode:
- clip-on
- Net Weight:
- 0.322 kg
- Device Application:
- distribution
- Curve Code:
- C
- Earth-Leakage Protection:
- separate block
- Mercury Free:
- Yes
- Poles Description:
- 3P + N
- [Ics] Rated Service Breaking Capacity:
- 7.5 kA 75 % EN/IEC 60947-2 - 415 V AC 50/60 Hz
- Network Type:
- AC
- [Uimp] Rated Impulse Withstand Voltage:
- 4 kVEN/IEC 60947-2
- Standards:
- EN/IEC 60947-2
- Circularity Profile:
- N/A
- Mounting Support:
- DIN rail
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Ambient Air Temperature For Storage:
- -40-70 °C
- Width:
- 54 mm
- Tropicalisation:
- 2 IEC 60068-1
- Neutral Position:
- left
- Height:
- 81 mm
- Electrical Durability:
- 10000 cycles
- Wire Stripping Length:
- 13 mm for top or bottom connection
- Tightening Torque:
- 2-2 N.m top or bottom
- Provision For Padlocking:
- padlockable
- Mechanical Durability:
- 20000 cycles
- Contact Position Indicator:
- yes
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Connections - Terminals:
- tunnel type terminal top or bottom) 0.75-16 mm² - rigid || tunnel type terminal top or bottom) 0.33-10 mm² - flexible || tunnel type terminal top or bottom) 0.33-10 mm² - flexible with ferrule
- Range:
- Multi9
- [Ui] Rated Insulation Voltage:
- 500 V AC 50/60 Hz EN/IEC 60947-2
- Line Rated Current:
- 25 A 50 °C EN/IEC 60947-2
- Trip Unit Technology:
- thermal-magnetic
- Breaking Capacity:
- 10 kA Icu 415 V AC 50/60 Hz between phases EN/IEC 60947-2
- Pollution Degree:
- 3 EN/IEC 60947-2
- Brochure:
- View
- Datasheet:
- View