Schneider Electric M9R81225 Multi9 Gfp 2P 25A 26Ma A-Si 120-240V

(No reviews yet) Write a Review
SKU:
M9R81225
UPC:
3606481198419
Condition:
New
Sustainable Offer Status:
Green Premium product
Pollution Degree:
3
Product Name:
Multi9 GFP
Utilisation Category:
AC-23A EN/IEC 61008-1
Connections - Terminals:
tunnel type terminals top or bottom) 1-25 mm² AWG 18...AWG 3) - flexible || tunnel type terminals top or bottom) 1-35 mm² AWG 18...AWG 2) - rigid || tunnel type terminals top or bottom) 1-25 mm² AWG 18...AWG 3) - flexible with ferrule
Environmental Disclosure:
ENVPEP2301023EN
Rohs Exemption Information:
Yes
Earth-Leakage Sensitivity:
26 mA UL 1053 || 30 mA EN/IEC 61008-1
Ip Degree Of Protection:
IP20 conforming to IEC 60529 || IP40 (modular enclosure) conforming to IEC 60529
Line Rated Current:
25 A 40 °C EN/IEC 61008-1
Height:
81 mm
Network Frequency:
50/60 Hz
Circularity Profile:
N/A
Poles Description:
2P
Ambient Air Temperature For Storage:
-40-70 °C
Device Application:
distribution
Rated Breaking And Making Capacity:
Idm 1500 A EN/IEC 61008-1
Electromagnetic Compatibility:
8/20 µs impulse withstand, 3000 A EN/IEC 61008-1
Depth:
60 mm
Mounting Support:
DIN rail
Product Certifications:
IEC || UL
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Relative Humidity:
95-95 % 55-55 °C
Earth-Leakage Protection Time Delay:
instantaneous
Rated Conditional Short-Circuit Current:
Inc 10 kA 100 A gG
[Ui] Rated Insulation Voltage:
440 V AC 50/60 Hz
[Uimp] Rated Impulse Withstand Voltage:
6 kVEN/IEC 61008-1
Mercury Free:
Yes
Standards:
EN/IEC 61008-1 || UL 1053
Range:
Multi9
Local Signalling:
ON, OFF, fault trip
Mounting Mode:
clip-on
Net Weight:
0.22 kg
9 Mm Pitches:
4
Product Or Component Type:
residual current circuit breaker (RCCB)
Earth-Leakage Protection Class:
type A-SI (Super Immunised)
Width:
36 mm
Eu Rohs Directive:
Compliant with Exemptions
[Ue] Rated Operational Voltage:
120/240 V AC 60 Hz || 240 V AC 50 Hz
Color:
Gray
Wire Stripping Length:
14 mm for top or bottom connection
Mechanical Durability:
20000 cycles
Tropicalisation:
2 IEC 60068-1
Contact Position Indicator:
yes
Residual Current Tripping Technology:
voltage independent
Control Type:
toggle
Network Type:
AC
Locking Options Description:
padlocking in OFF position
Device Short Name:
GFP
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Neutral Position:
left
Ambient Air Temperature For Operation:
-25-60 °C
Tightening Torque:
3.5-3.5 N.m top or bottom
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
$633.00

Description

This Multi GFP product is a residual current circuit breaker (RCCB). It is a 2P circuit breaker with 25A In rated current, 26mA earth leakage sensitivity and A-SI type protection class. It protects persons against electric shock by direct contact. It also protects installations against fire risks. The tripping upon fault is indicated by a red mechanical status indicator on the front panel. The A-SI type offers enhanced immunity to electrical disturbances. This product is dedicated to original equipment manufacturers (OEM) and control panel builders in indisutrial and tertiary buildings. It is compliant with IEC/EN 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 1500A. The (Inc/IΔc) conditional rated short circuit current is 10kA. It has a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 230VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 6kV. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 81mm x (D) 60mm. The weight is 0.22kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -25°C to 60°C. The storage temperature is from -40°C to 70°C.