Schneider Electric MGA36600JK Molded Case Circuit Breaker 600V 600A
Schneider Electric
$8,491.00
$1200 Minimum Order for Non-stock Items or $60 Addl Schneider Handling Fee Applies
PowerPacT M-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT M-Frame circuit breakers have either a fixed long time electronic trip unit or an adjustable amperage version. This circuit breaker has an electronic trip unit, ET 1.0. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT M circuit breakers are available in 2 and 3-pole unit mount or I-Line construction. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT M, 600A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. This unit has a horizontal mount Kirk lock. PowerPacT M circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Suitability For Isolation:
- yes IEC 60947-2
- Ip Degree Of Protection:
- IP40
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
- Color:
- Black
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Width:
- 8.27 in
- Net Weight:
- 29 lb(US)
- Ambient Air Temperature For Operation:
- -25-70 °C
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Warranty:
- 18 months
- Height:
- 12.86 in
- Mounting Mode:
- I-Line bracket)
- Product Or Component Type:
- circuit breaker
- Wire Stripping Length:
- 25 mm
- Magnetic Tripping Current:
- 1200-6000 A
- Quantity Per Set:
- 1
- Accessory / Separate Part Type:
- keylock accessories
- Sustainable Offer Status:
- Green Premium product
- Breaking Capacity:
- AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Trip Unit Name:
- ET 1.0
- Product Certifications:
- UL || CSA || NOM
- Utilisation Category:
- category A
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Eu Rohs Directive:
- Compliant with Exemptions
- Mercury Free:
- Yes
- Type Of Keylock:
- Kirk
- Mounting Height:
- 9 in
- Electrical Connection:
- I-Line connection, line || lugs, load
- Pollution Degree:
- 3 IEC 60947-1
- Range:
- PowerPact
- Control Type:
- operating handle
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz UL 489
- Environmental Disclosure:
- ENVPEP2206030EN
- [Ics] Rated Service Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Continuous Current Rating:
- 0.8
- Pvc Free:
- Yes
- Poles Description:
- 3P
- Product Name:
- PowerPact M
- Depth:
- 8.05 in
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Quality Labels:
- CE
- Mounting Support:
- bracket
- Circularity Profile:
- ENVEOLI2206030EN
- Rohs Exemption Information:
- Yes
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
- Network Frequency:
- 50/60 Hz
- Tightening Torque:
- 50-50 N.m 95-240 mm² (3 x AWG 3/0...3 x 500 kcmil)
- Local Signalling:
- 1 trip indicator green)
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Circuit Breaker Application:
- HACR rated
- Long Time Pick-Up Adjustment Range:
- 300...800 A
- Trip Unit Technology:
- electronic, basic, ET 1.0,
- Device Application:
- distribution
- Breaking Capacity Code:
- G
- Awg Gauge:
- 3 x AWG 3/0...3 x 500 kcmil aluminium/copper
- Terminal Identifier:
- AL800M23K
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Line Rated Current:
- 600-600 A
- Ambient Air Temperature For Storage:
- -50-85 °C
- Catalog:
- View
- Datasheet:
- View