Schneider Electric MGL36300 Molded Case Circuit Breaker 600V 300A

(No reviews yet) Write a Review
SKU:
MGL36300
UPC:
785901507635
Condition:
New
Mercury Free:
Yes
Circuit Breaker Application:
HACR rated
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Pollution Degree:
3 IEC 60947-1
Color:
Black
Environmental Disclosure:
ENVPEP2206030EN
Utilisation Category:
category A
Net Weight:
29 lb(US)
Local Signalling:
1 trip indicator green)
Wire Stripping Length:
25 mm
Mounting Support:
lug
Mounting Mode:
unit mount lug)
Awg Gauge:
3 x AWG 3/0...3 x 500 kcmil aluminium/copper
Trip Unit Technology:
electronic, basic, ET 1.0,
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Depth:
8.05 in
Long Time Pick-Up Adjustment Range:
300...800 A
Ip Degree Of Protection:
IP40
Range:
PowerPact
Circularity Profile:
ENVEOLI2206030EN
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
Suitability For Isolation:
yes IEC 60947-2
Eu Rohs Directive:
Compliant with Exemptions
Product Certifications:
UL || CSA || NOM
Quantity Per Set:
1
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...3 x 500 kcmil)
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Device Application:
distribution
Quality Labels:
CE
Width:
8.27 in
Magnetic Tripping Current:
600-3000 A
Continuous Current Rating:
0.8
Network Frequency:
50/60 Hz
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Product Name:
PowerPact M
Poles Description:
3P
Terminal Identifier:
AL800M23K
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Electrical Connection:
lugs, load || lugs, line
Product Or Component Type:
circuit breaker
Pvc Free:
Yes
Ambient Air Temperature For Operation:
-25-70 °C
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Rohs Exemption Information:
Yes
Breaking Capacity Code:
G
Trip Unit Name:
ET 1.0
Control Type:
operating handle
Ambient Air Temperature For Storage:
-50-85 °C
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
Sustainable Offer Status:
Green Premium product
Line Rated Current:
300-300 A
Warranty:
18 months
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Height:
12.86 in
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric MGL36300 Molded Case Circuit Breaker 600V 300A
  • Schneider Electric MGL36300 Molded Case Circuit Breaker 600V 300A
  • Schneider Electric MGL36300 Molded Case Circuit Breaker 600V 300A
$7,560.00

Description

PowerPacT M-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT M-Frame circuit breakers have either a fixed long time electronic trip unit or an adjustable amperage version. This circuit breaker has an electronic trip unit, ET 1.0. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT M circuit breakers are available in 2 and 3-pole unit mount or I-Line construction. This unit has lugs on both the line and load sides. This PowerPacT M, 300A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT M circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose