Schneider Electric MGL36800E10SA Molded Case Circuit Breaker 600V 800A

(No reviews yet) Write a Review
SKU:
MGL36800E10SA
UPC:
3606486284902
Condition:
New
Communication Interface:
Modbus
Sustainable Offer Status:
Green Premium product
Height:
12.86 in
Quality Labels:
CE
Width:
8.27 in
Pvc Free:
Yes
Line Rated Current:
300-800 A
Rohs Exemption Information:
Yes
Range:
PowerPact
Quantity Per Set:
1
Suitability For Isolation:
yes IEC 60947-2
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Mounting Support:
lug
Product Certifications:
UL || CSA || NOM
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Ip Degree Of Protection:
IP40
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Long Time Pick-Up Adjustment Range:
300...800 A
Circuit Breaker Application:
HACR rated
Magnetic Tripping Current:
1600-8000 A
Ambient Air Temperature For Storage:
-50-85 °C
Pollution Degree:
3 IEC 60947-1
Continuous Current Rating:
0.8
Ambient Air Temperature For Operation:
-25-70 °C
Color:
Black
Device Application:
distribution
Breaking Capacity Code:
G
Depth:
8.05 in
Environmental Disclosure:
ENVPEP2206030EN
Trip Unit Name:
ET 1.0
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Mercury Free:
Yes
Electrical Connection:
lugs, load || lugs, line
Terminal Identifier:
AL800M23K
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
Accessory / Separate Part Type:
shunt trip 24...30 V AC/DC || communication module
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Net Weight:
29 lb(US)
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...3 x 500 kcmil)
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Wire Stripping Length:
25 mm
Eu Rohs Directive:
Compliant with Exemptions
Utilisation Category:
category A
Local Signalling:
1 trip indicator green)
Poles Description:
3P
Product Or Component Type:
circuit breaker
Network Frequency:
50/60 Hz
Mounting Mode:
unit mount lug)
Control Type:
operating handle
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile:
ENVEOLI2206030EN
Trip Unit Technology:
electronic, basic, ET 1.0,
Product Name:
PowerPact M
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Awg Gauge:
3 x AWG 3/0...3 x 500 kcmil aluminium/copper
Catalog:
View
Datasheet:
View
  • Schneider Electric MGL36800E10SA Molded Case Circuit Breaker 600V 800A
  • Schneider Electric MGL36800E10SA Molded Case Circuit Breaker 600V 800A
  • Schneider Electric MGL36800E10SA Molded Case Circuit Breaker 600V 800A
$10,682.00

Description

PowerPacT M-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT M-Frame circuit breakers have either a fixed long time electronic trip unit or an adjustable amperage version. This circuit breaker has the adjustable amperage option, allowing trip setting changes between 300A to 800A using a selector switch. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT M circuit breakers are available in 2 and 3-pole unit mount or I-Line construction. This unit has lugs on both the line and load sides. This PowerPacT M, 300A to 800A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. This unit includes a factory installed 120VAC shunt trip. PowerPacT M circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.