- Quality Labels:
- CE
- Color:
- Black
- Trip Unit Name:
- ET 1.0
- Product Certifications:
- UL || CSA || NOM
- Pvc Free:
- Yes
- Sustainable Offer Status:
- Green Premium product
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
- Network Frequency:
- 50/60 Hz
- Long Time Pick-Up Adjustment Range:
- 300...800 A
- Circuit Breaker Application:
- HACR rated
- Device Application:
- distribution
- Quantity Per Set:
- 1
- Eu Rohs Directive:
- Compliant with Exemptions
- Product Or Component Type:
- circuit breaker
- Width:
- 8.27 in
- Breaking Capacity Code:
- J
- Mercury Free:
- Yes
- Ip Degree Of Protection:
- IP40
- Control Type:
- operating handle
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
- Pollution Degree:
- 3 IEC 60947-1
- Continuous Current Rating:
- 0.8
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Local Signalling:
- 1 trip indicator green)
- Tightening Torque:
- 50-50 N.m 95-240 mm² (3 x AWG 3/0...3 x 500 kcmil)
- Rohs Exemption Information:
- Yes
- Range:
- PowerPact
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Wire Stripping Length:
- 25 mm
- Environmental Disclosure:
- ENVPEP2206030EN
- Breaking Capacity:
- AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Line Rated Current:
- 450-450 A
- Mounting Mode:
- unit mount lug)
- Mounting Support:
- lug
- Awg Gauge:
- 3 x AWG 3/0...3 x 500 kcmil aluminium/copper
- Terminal Identifier:
- AL800M23K
- Suitability For Isolation:
- yes IEC 60947-2
- Ambient Air Temperature For Operation:
- -25-70 °C
- Product Name:
- PowerPact M
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Trip Unit Technology:
- electronic, basic, ET 1.0,
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- [Ics] Rated Service Breaking Capacity:
- 35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Height:
- 12.86 in
- Warranty:
- 18 months
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz UL 489
- Depth:
- 8.05 in
- Electrical Connection:
- lugs, load || lugs, line
- Net Weight:
- 29 lb(US)
- Circularity Profile:
- ENVEOLI2206030EN
- Magnetic Tripping Current:
- 900-4500 A
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Ambient Air Temperature For Storage:
- -50-85 °C
- Utilisation Category:
- category A
- Poles Description:
- 3P