Schneider Electric PGA36100U31A Molded Case Circuit Breaker 600V 1000A

(No reviews yet) Write a Review
SKU:
PGA36100U31A
UPC:
7.85902E+11
Condition:
New
Electrical Connection:
I-Line connection, line || lugs, load
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Pvc Free:
Yes
Sustainable Offer Status:
Green Premium product
Ambient Air Temperature For Storage:
-50-85 °C
Height:
16.16 in
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Continuous Current Rating:
0.8
Line Rated Current:
1000-1000 A
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Quality Labels:
CE
Net Weight:
32 lb(US)
Product Certifications:
UL || CSA || NOM
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Phase Connection:
ABC
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Tightening Torque:
50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Depth:
8.05 in
Mounting Support:
bracket
Trip Unit Technology:
electronic, standard, MicroLogic 3.0, LI
Ip Degree Of Protection:
front cover IP40
Mercury Free:
Yes
Circuit Breaker Application:
HACR rated
Trip Unit Name:
MicroLogic 3.0
Circularity Profile:
ENVEOLI2206033EN
Quantity Per Set:
1
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Range:
PowerPact
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Network Frequency:
50/60 Hz
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Local Signalling:
overload 1 trip indicator green) || 1 trip indicator green)
Eu Rohs Directive:
Compliant with Exemptions
Device Application:
distribution
Mounting Mode:
I-Line bracket)
Breaking Capacity Code:
G
Control Type:
toggle
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Wire Stripping Length:
30 mm
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Rohs Exemption Information:
Yes
Pollution Degree:
3 IEC 60947-1
Mounting Height:
9 in
Ambient Air Temperature For Operation:
-2-70 °C
Product Name:
PowerPact P
Environmental Disclosure:
ENVPEP2206033EN
Poles Description:
3P
Width:
8.27 in
Awg Gauge:
4 x AWG 3/0...500 kcmil aluminium/copper
Product Or Component Type:
circuit breaker
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
Terminal Identifier:
AL1200P25K
Warranty:
18 months
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric PGA36100U31A Molded Case Circuit Breaker 600V 1000A
  • Schneider Electric PGA36100U31A Molded Case Circuit Breaker 600V 1000A
$20,790.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 3.0 trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 1000A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.