- Electrical Connection:
- I-Line connection, line || lugs, load
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz UL 489
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Pvc Free:
- Yes
- Sustainable Offer Status:
- Green Premium product
- Ambient Air Temperature For Storage:
- -50-85 °C
- Height:
- 16.16 in
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Continuous Current Rating:
- 0.8
- Line Rated Current:
- 1000-1000 A
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Quality Labels:
- CE
- Net Weight:
- 32 lb(US)
- Product Certifications:
- UL || CSA || NOM
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Phase Connection:
- ABC
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
- Tightening Torque:
- 50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
- Depth:
- 8.05 in
- Mounting Support:
- bracket
- Trip Unit Technology:
- electronic, standard, MicroLogic 3.0, LI
- Ip Degree Of Protection:
- front cover IP40
- Mercury Free:
- Yes
- Circuit Breaker Application:
- HACR rated
- Trip Unit Name:
- MicroLogic 3.0
- Circularity Profile:
- ENVEOLI2206033EN
- Quantity Per Set:
- 1
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Range:
- PowerPact
- Long Time Pick-Up Adjustment Range:
- 0.4...1 x Ir
- Network Frequency:
- 50/60 Hz
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Local Signalling:
- overload 1 trip indicator green) || 1 trip indicator green)
- Eu Rohs Directive:
- Compliant with Exemptions
- Device Application:
- distribution
- Mounting Mode:
- I-Line bracket)
- Breaking Capacity Code:
- G
- Control Type:
- toggle
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Wire Stripping Length:
- 30 mm
- [Ics] Rated Service Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Rohs Exemption Information:
- Yes
- Pollution Degree:
- 3 IEC 60947-1
- Mounting Height:
- 9 in
- Ambient Air Temperature For Operation:
- -2-70 °C
- Product Name:
- PowerPact P
- Environmental Disclosure:
- ENVPEP2206033EN
- Poles Description:
- 3P
- Width:
- 8.27 in
- Awg Gauge:
- 4 x AWG 3/0...500 kcmil aluminium/copper
- Product Or Component Type:
- circuit breaker
- Breaking Capacity:
- AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Terminal Identifier:
- AL1200P25K
- Warranty:
- 18 months