- Long Time Pick-Up Adjustment Range:
- 0.4...1 x Ir
- Wire Stripping Length:
- 25 mm
- Network Frequency:
- 50/60 Hz
- Circularity Profile:
- ENVEOLI2206033EN
- Mercury Free:
- Yes
- Product Or Component Type:
- circuit breaker
- Eu Rohs Directive:
- Compliant with Exemptions
- Depth:
- 8.05 in
- Warranty:
- 18 months
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Ambient Air Temperature For Operation:
- -2-70 °C
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Device Application:
- distribution
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Trip Unit Name:
- MicroLogic 3.0
- Product Name:
- PowerPact P
- Circuit Breaker Application:
- HACR rated
- Continuous Current Rating:
- 1
- Product Certifications:
- UL || CSA || NOM
- Sustainable Offer Status:
- Green Premium product
- Tightening Torque:
- 50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz UL 489
- Trip Unit Technology:
- electronic, standard, MicroLogic 3.0, LI
- Rohs Exemption Information:
- Yes
- Breaking Capacity Code:
- G
- Poles Description:
- 3P
- Line Rated Current:
- 800-800 A
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Quantity Per Set:
- 1
- Ambient Air Temperature For Storage:
- -50-85 °C
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
- Control Type:
- toggle
- Net Weight:
- 32 lb(US)
- Pvc Free:
- Yes
- Ip Degree Of Protection:
- front cover IP40
- [Ics] Rated Service Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Environmental Disclosure:
- ENVPEP2206033EN
- Breaking Capacity:
- AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Range:
- PowerPact
- Awg Gauge:
- 3 x AWG 3/0...500 kcmil aluminium/copper
- Local Signalling:
- overload 1 1 LED amber) || 1 trip indicator green)
- Height:
- 12.86 in
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Pollution Degree:
- 3 IEC 60947-1
- Quality Labels:
- CE
- Terminal Identifier:
- AL800M23K
- Electrical Connection:
- lugs, load || lugs, line
- Width:
- 8.27 in
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2