Schneider Electric

Schneider Electric PGL36080CU31A Molded Case Circuit Breaker 600V 800A

(No reviews yet) Write a Review
SKU:
PGL36080CU31A
UPC:
785901536567
Condition:
New
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Wire Stripping Length:
25 mm
Network Frequency:
50/60 Hz
Circularity Profile:
ENVEOLI2206033EN
Mercury Free:
Yes
Product Or Component Type:
circuit breaker
Eu Rohs Directive:
Compliant with Exemptions
Depth:
8.05 in
Warranty:
18 months
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Ambient Air Temperature For Operation:
-2-70 °C
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Device Application:
distribution
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Trip Unit Name:
MicroLogic 3.0
Product Name:
PowerPact P
Circuit Breaker Application:
HACR rated
Continuous Current Rating:
1
Product Certifications:
UL || CSA || NOM
Sustainable Offer Status:
Green Premium product
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Trip Unit Technology:
electronic, standard, MicroLogic 3.0, LI
Rohs Exemption Information:
Yes
Breaking Capacity Code:
G
Poles Description:
3P
Line Rated Current:
800-800 A
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Quantity Per Set:
1
Ambient Air Temperature For Storage:
-50-85 °C
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Control Type:
toggle
Net Weight:
32 lb(US)
Pvc Free:
Yes
Ip Degree Of Protection:
front cover IP40
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Environmental Disclosure:
ENVPEP2206033EN
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
Range:
PowerPact
Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
Local Signalling:
overload 1 1 LED amber) || 1 trip indicator green)
Height:
12.86 in
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Pollution Degree:
3 IEC 60947-1
Quality Labels:
CE
Terminal Identifier:
AL800M23K
Electrical Connection:
lugs, load || lugs, line
Width:
8.27 in
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Brochure:
View
Catalog:
View
Datasheet:
View
$21,510.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 3.0 trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 800A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 100%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked. For use on load end of circuit breaker only. For use in UL 508 Industrial Control applications. For use in UL 1995/CSA C22.2 No.
View AllClose