Schneider Electric PGL36080U44A Molded Case Circuit Breaker 600V 800A

(No reviews yet) Write a Review
SKU:
PGL36080U44A
UPC:
7.85902E+11
Condition:
New
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Control Type:
toggle
Net Weight:
32 lb(US)
Continuous Current Rating:
0.8
Electrical Connection:
lugs, load || lugs, line
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Mercury Free:
Yes
Product Certifications:
UL || CSA || NOM
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Poles Description:
3P
Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
Circuit Breaker Application:
HACR rated
Trip Unit Name:
MicroLogic 6.0 A
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Range:
PowerPact
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Height:
12.86 in
Depth:
8.05 in
Ambient Air Temperature For Operation:
-2-70 °C
Breaking Capacity Code:
G
Device Application:
distribution
Line Rated Current:
800-800 A
Local Signalling:
overload 1 1 LED amber) || 1 flag green) || trip causes 4 trip indicator red)
Terminal Identifier:
AL800M23K
Network Frequency:
50/60 Hz
Ambient Air Temperature For Storage:
-50-85 °C
Trip Unit Technology:
electronic, ammeter, MicroLogic 6.0 A, LSIG
Circularity Profile:
ENVEOLI2206033EN
Ip Degree Of Protection:
front cover IP40
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Warranty:
18 months
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Rohs Exemption Information:
Yes
Environmental Disclosure:
ENVPEP2206033EN
Pollution Degree:
3 IEC 60947-1
Eu Rohs Directive:
Compliant with Exemptions
Width:
8.27 in
Product Or Component Type:
circuit breaker
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Quantity Per Set:
1
Wire Stripping Length:
25 mm
Product Name:
PowerPact P
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Quality Labels:
CE
Pvc Free:
Yes
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Sustainable Offer Status:
Green Premium product
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric PGL36080U44A Molded Case Circuit Breaker 600V 800A
  • Schneider Electric PGL36080U44A Molded Case Circuit Breaker 600V 800A
$18,909.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Ammeter with a 6.0A trip unit and an LSIG function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 800A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose