Schneider Electric PGL36100U31AMO Molded Case Circuit Breaker 600V 1000A

(No reviews yet) Write a Review
SKU:
PGL36100U31AMO
UPC:
7.85902E+11
Condition:
New
Tightening Torque:
50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Poles Description:
3P
Circuit Breaker Application:
HACR rated
Eu Rohs Directive:
Compliant with Exemptions
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Network Frequency:
50/60 Hz
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Sustainable Offer Status:
Green Premium product
Accessory / Separate Part Type:
motor operator 24...30 V DC
Net Weight:
32 lb(US)
Product Certifications:
UL || CSA || NOM
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Environmental Disclosure:
ENVPEP2206033EN
Depth:
8.05 in
Pollution Degree:
3 IEC 60947-1
Electrical Connection:
lugs, load || lugs, line
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Awg Gauge:
4 x AWG 3/0...500 kcmil aluminium/copper
Quality Labels:
CE
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Product Name:
PowerPact P
Trip Unit Name:
MicroLogic 3.0
Circularity Profile:
ENVEOLI2206033EN
Ip Degree Of Protection:
front cover IP40
Range:
PowerPact
Trip Unit Technology:
electronic, standard, MicroLogic 3.0, LI
Line Rated Current:
1000-1000 A
Quantity Per Set:
1
Height:
16.16 in
Rohs Exemption Information:
Yes
Breaking Capacity Code:
G
Product Or Component Type:
circuit breaker
Ambient Air Temperature For Storage:
-50-85 °C
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Control Type:
motor mechanism
Local Signalling:
1 trip indicator green)
Mercury Free:
Yes
Ambient Air Temperature For Operation:
-2-70 °C
Wire Stripping Length:
30 mm
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Terminal Identifier:
AL1200P25K
Warranty:
18 months
Pvc Free:
Yes
Width:
8.27 in
Device Application:
distribution
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Continuous Current Rating:
0.8
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Brochure:
View
Catalog:
View
Datasheet:
View
$24,926.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 3.0 trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 1000A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. This unit includes a 24VDC motor operator. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose