Schneider Electric PGL36100U41A Molded Case Circuit Breaker 600V 1000A

(No reviews yet) Write a Review
SKU:
PGL36100U41A
UPC:
7.85901E+11
Condition:
New
Product Name:
PowerPact P
Trip Unit Name:
MicroLogic 3.0 A
Ambient Air Temperature For Storage:
-50-85 °C
Quality Labels:
CE
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Network Frequency:
50/60 Hz
Warranty:
18 months
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
Local Signalling:
1 trip indicator green)
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Circuit Breaker Application:
HACR rated
Depth:
8.05 in
Environmental Disclosure:
ENVPEP2206033EN
Ip Degree Of Protection:
front cover IP40
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Product Certifications:
UL || CSA || NOM
Pollution Degree:
3 IEC 60947-1
Product Or Component Type:
circuit breaker
Device Application:
distribution
Ambient Air Temperature For Operation:
-2-70 °C
Terminal Identifier:
AL1200P25K
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Breaking Capacity Code:
G
Height:
16.16 in
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Eu Rohs Directive:
Compliant with Exemptions
Continuous Current Rating:
0.8
Electrical Connection:
lugs, load || lugs, line
Sustainable Offer Status:
Green Premium product
Width:
8.27 in
Poles Description:
3P
Mercury Free:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Control Type:
toggle
Wire Stripping Length:
30 mm
Trip Unit Technology:
electronic, ammeter, MicroLogic 3.0 A, LI
Quantity Per Set:
1
Range:
PowerPact
Line Rated Current:
1000-1000 A
Tightening Torque:
50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Net Weight:
32 lb(US)
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Circularity Profile:
ENVEOLI2206033EN
Pvc Free:
Yes
Awg Gauge:
4 x AWG 3/0...500 kcmil aluminium/copper
Rohs Exemption Information:
Yes
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric PGL36100U41A Molded Case Circuit Breaker 600V 1000A
  • Schneider Electric PGL36100U41A Molded Case Circuit Breaker 600V 1000A
$20,688.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Ammeter with a 3.0A trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 1000A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.