Schneider Electric

Schneider Electric PGL36120CU33A Molded Case Circuit Breaker 600V 1200A

(No reviews yet) Write a Review
SKU:
PGL36120CU33A
UPC:
785901571278
Condition:
New
Awg Gauge:
4 x AWG 3/0...500 kcmil aluminium/copper
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Ip Degree Of Protection:
front cover IP40
Product Certifications:
UL || CSA || NOM
Tightening Torque:
50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Quantity Per Set:
1
Ambient Air Temperature For Operation:
-2-70 °C
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Circularity Profile:
ENVEOLI2206033EN
Continuous Current Rating:
1
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Circuit Breaker Application:
HACR rated
Pollution Degree:
3 IEC 60947-1
Sustainable Offer Status:
Green Premium product
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Electrical Connection:
lugs, load || lugs, line
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Quality Labels:
CE
Product Or Component Type:
circuit breaker
Terminal Identifier:
AL1200P25K
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Depth:
8.05 in
Range:
PowerPact
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
Control Type:
toggle
Device Application:
distribution
Pvc Free:
Yes
Eu Rohs Directive:
Compliant with Exemptions
Mercury Free:
Yes
Line Rated Current:
1200-1200 A
Trip Unit Technology:
electronic, standard, MicroLogic 5.0, LSI
Product Name:
PowerPact P
Net Weight:
32 lb(US)
Poles Description:
3P
Rohs Exemption Information:
Yes
Trip Unit Name:
MicroLogic 5.0
Ambient Air Temperature For Storage:
-50-85 °C
Warranty:
18 months
Breaking Capacity Code:
G
Environmental Disclosure:
ENVPEP2206033EN
Width:
8.27 in
Wire Stripping Length:
30 mm
Local Signalling:
1 trip indicator green)
Network Frequency:
50/60 Hz
Height:
16.16 in
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Brochure:
View
Catalog:
View
Datasheet:
View
$30,540.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 5.0 trip unit and an LSI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 1200A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 100%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose