Schneider Electric PGL36120U41A Molded Case Circuit Breaker 600V 1200A

(No reviews yet) Write a Review
SKU:
PGL36120U41A
UPC:
785901977650
Condition:
New
Quality Labels:
CE
Ip Degree Of Protection:
front cover IP40
Height:
16.16 in
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Eu Rohs Directive:
Compliant with Exemptions
Control Type:
toggle
Ambient Air Temperature For Operation:
-2-70 °C
Network Frequency:
50/60 Hz
Trip Unit Technology:
electronic, ammeter, MicroLogic 3.0 A, LI
Warranty:
18 months
Environmental Disclosure:
ENVPEP2206033EN
Product Name:
PowerPact P
Quantity Per Set:
1
Product Certifications:
UL || CSA || NOM
Wire Stripping Length:
30 mm
Width:
8.27 in
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Net Weight:
32 lb(US)
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Circularity Profile:
ENVEOLI2206033EN
Sustainable Offer Status:
Green Premium product
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Rohs Exemption Information:
Yes
Ambient Air Temperature For Storage:
-50-85 °C
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Range:
PowerPact
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Local Signalling:
1 trip indicator green)
Trip Unit Name:
MicroLogic 3.0 A
Line Rated Current:
1200-1200 A
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Awg Gauge:
4 x AWG 3/0...500 kcmil aluminium/copper
Product Or Component Type:
circuit breaker
Electrical Connection:
lugs, load || lugs, line
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Continuous Current Rating:
0.8
Mercury Free:
Yes
Depth:
8.05 in
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Device Application:
distribution
Tightening Torque:
50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Poles Description:
3P
Breaking Capacity Code:
G
Pollution Degree:
3 IEC 60947-1
Pvc Free:
Yes
Terminal Identifier:
AL1200P25K
Circuit Breaker Application:
HACR rated
Brochure:
View
Catalog:
View
Datasheet:
View
$20,688.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Ammeter with a 3.0A trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 1200A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.