SKU:
PJA36060CU31A
UPC:
785901433293
Condition:
New
Depth:
8.05 in
Quantity Per Set:
1
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Sustainable Offer Status:
Green Premium product
Control Type:
toggle
Mounting Support:
bracket
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Ambient Air Temperature For Operation:
-2-70 °C
Eu Rohs Directive:
Compliant with Exemptions
Trip Unit Technology:
electronic, standard, MicroLogic 3.0, LI
Net Weight:
32 lb(US)
Breaking Capacity Code:
J
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Range:
PowerPact
Continuous Current Rating:
1
Wire Stripping Length:
25 mm
Product Or Component Type:
circuit breaker
Quality Labels:
CE
Ip Degree Of Protection:
front cover IP40
Circularity Profile:
ENVEOLI2206033EN
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Width:
8.27 in
Poles Description:
3P
Circuit Breaker Application:
HACR rated
Height:
12.86 in
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Device Application:
distribution
Pollution Degree:
3 IEC 60947-1
Mounting Mode:
I-Line bracket)
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Environmental Disclosure:
ENVPEP2206033EN
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Pvc Free:
Yes
Mounting Height:
9 in
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
[Ics] Rated Service Breaking Capacity:
35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Product Name:
PowerPact P
Rohs Exemption Information:
Yes
Trip Unit Name:
MicroLogic 3.0
Terminal Identifier:
AL800M23K
Mercury Free:
Yes
Electrical Connection:
I-Line connection, line || lugs, load
Phase Connection:
ABC
Warranty:
18 months
Line Rated Current:
600-600 A
Ambient Air Temperature For Storage:
-50-85 °C
Local Signalling:
1 trip indicator green)
Product Certifications:
UL || CSA || NOM
Network Frequency:
50/60 Hz
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Brochure:
View
Catalog:
View
Datasheet:
View
$23,897.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 3.0 trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 600A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 100% with an ABC phase connection. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.