- Tightening Torque:
- 50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
- Depth:
- 8.05 in
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Long Time Pick-Up Adjustment Range:
- 0.4...1 x Ir
- Mounting Support:
- bracket
- Continuous Current Rating:
- 0.8
- Product Name:
- PowerPact P
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
- Mounting Mode:
- I-Line bracket)
- Quality Labels:
- CE
- Ambient Air Temperature For Operation:
- -2-70 °C
- Line Rated Current:
- 600-600 A
- Warranty:
- 18 months
- Mercury Free:
- Yes
- Breaking Capacity Code:
- J
- Range:
- PowerPact
- Quantity Per Set:
- 1
- Terminal Identifier:
- AL800M23K
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Network Frequency:
- 50/60 Hz
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Device Application:
- distribution
- Product Or Component Type:
- circuit breaker
- Trip Unit Technology:
- electronic, standard, MicroLogic 3.0, LI
- Mounting Height:
- 9 in
- Net Weight:
- 32 lb(US)
- Circularity Profile:
- ENVEOLI2206033EN
- Pollution Degree:
- 3 IEC 60947-1
- Ambient Air Temperature For Storage:
- -50-85 °C
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Ip Degree Of Protection:
- front cover IP40
- Eu Rohs Directive:
- Compliant with Exemptions
- Phase Connection:
- ABC
- Poles Description:
- 3P
- Breaking Capacity:
- AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Pvc Free:
- Yes
- [Ics] Rated Service Breaking Capacity:
- 35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Wire Stripping Length:
- 25 mm
- Control Type:
- toggle
- Height:
- 12.86 in
- Width:
- 8.27 in
- Circuit Breaker Application:
- HACR rated
- Local Signalling:
- 1 trip indicator green)
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Awg Gauge:
- 3 x AWG 3/0...500 kcmil aluminium/copper
- Sustainable Offer Status:
- Green Premium product
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Trip Unit Name:
- MicroLogic 3.0
- Product Certifications:
- UL || CSA || NOM
- Rohs Exemption Information:
- Yes
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz UL 489
- Environmental Disclosure:
- ENVPEP2206033EN
- Electrical Connection:
- I-Line connection, line || lugs, load
- QN-QUOTE-REQUEST: