Schneider Electric PJA36060U44A Molded Case Circuit Breaker 600V 600A

(No reviews yet) Write a Review
SKU:
PJA36060U44A
UPC:
785901497097
Condition:
New
Phase Connection:
ABC
Trip Unit Name:
MicroLogic 6.0 A
Pollution Degree:
3 IEC 60947-1
Mercury Free:
Yes
Rohs Exemption Information:
Yes
Network Frequency:
50/60 Hz
Environmental Disclosure:
ENVPEP2206033EN
Mounting Support:
bracket
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Poles Description:
3P
Electrical Connection:
I-Line connection, line || lugs, load
Continuous Current Rating:
0.8
Product Certifications:
UL || CSA || NOM
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Control Type:
toggle
Ip Degree Of Protection:
front cover IP40
[Ics] Rated Service Breaking Capacity:
35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Breaking Capacity Code:
J
Pvc Free:
Yes
Quantity Per Set:
1
Mounting Height:
9 in
Warranty:
18 months
Product Or Component Type:
circuit breaker
Circuit Breaker Application:
HACR rated
Width:
8.27 in
Device Application:
distribution
Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
Eu Rohs Directive:
Compliant with Exemptions
Circularity Profile:
ENVEOLI2206033EN
Line Rated Current:
600-600 A
Depth:
8.05 in
Quality Labels:
CE
Product Name:
PowerPact P
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Terminal Identifier:
AL800M23K
Sustainable Offer Status:
Green Premium product
Mounting Mode:
I-Line bracket)
Local Signalling:
1 trip indicator green)
Trip Unit Technology:
electronic, ammeter, MicroLogic 6.0 A, LSIG
Height:
12.86 in
Net Weight:
32 lb(US)
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Wire Stripping Length:
25 mm
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Range:
PowerPact
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Ambient Air Temperature For Operation:
-2-70 °C
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Ambient Air Temperature For Storage:
-50-85 °C
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Brochure:
View
Catalog:
View
Datasheet:
View
$20,486.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Ammeter with a 6.0A trip unit and an LSIG function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 600A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose